Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.993 kW
12/21/2025 14:13 (2034 days) Production Consumption NET Usage
Now 2.417 kW 0.424 kW -1.993 kW
Today 8.581 kWh (0.603 kW) 7.170 kWh (0.504 kW) -1.411 kWh (-0.099 kW)
  - This Week 8.581 kWh (14.464 kWh/day) 7.170 kWh (12.085 kWh/day) -1.411 kWh (-2.378 kWh/day)
  - This Month 183.487 kWh (8.910 kWh/day) 430.451 kWh (20.902 kWh/day) 246.964 kWh (11.992 kWh/day)
  - This Year 6.052 MWh (17.069 kWh/day) 7.347 MWh (20.719 kWh/day) 1.294 MWh (3.650 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.503 MWh (17.449 kW/day) 39.300 MWh (19.315 kW/day) 3.796 MWh (1.866 kW/day)
Lifetime Since Install 35.537 MWh 39.879 MWh 4.342 MWh
Voltage/Current 252.4 V / 9.6 A 252.3 V / 1.7 A 252.3 V / -7.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/23/2020 23:35 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.064 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 2.247 2.002 13.385 0.000 kW
2.168 kWh
0.000 kW
13.011 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 2.174 1.927 12.974
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.171 1.909 12.913
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.196 1.929 13.011
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.007 1.721 11.815
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 2.214 1.962 13.148
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 1.969 1.714 11.735 0.000 kW
2.041 kWh
0.000 kW
10.206 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 2.059 1.812 12.113
09 - 202217****** IQ7+ [5] VCOP 0.000 0.290 2.019 1.774 11.959
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 2.077 1.833 12.206
11 - 202224****** IQ7+M [5] VCOP 0.000 0.291 2.082 1.839 12.221
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.270 2.229 2.037 13.733 0.000 kW
2.212 kWh
0.000 kW
8.848 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.272 2.165 1.958 13.425
14 - 202216****** IQ7+ [5] VCOP 0.000 0.274 2.244 2.040 13.802
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 2.211 1.998 13.570
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.06 A (9.808 kW)
Remain Capacity/Energy 516.6 Ah (26.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 89.5 % State Of Health 96.2 %
Run Time 20m to full Report Date 2020-06-23 23:41
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.507 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 172.2 Ah (8.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 89.5 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-23 23:41
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.502 V 3.495 V 3.501 V 3.501 V 3.498 V 3.497 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.502 V 3.504 V 3.497 V 3.505 V 3.505 V 3.504 V 3.507 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -