Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 4.412 kW
06/15/2026 13:24 (2210 days) Production Consumption NET Usage
Now 4.370 kW -0.042 kW -4.412 kW
Today 16.085 kWh (1.199 kW) 4.038 kWh (0.301 kW) -12.047 kWh (-0.898 kW)
  - This Week 41.522 kWh (26.635 kWh/day) 28.436 kWh (18.241 kWh/day) -13.086 kWh (-8.394 kWh/day)
  - This Month 499.874 kWh (34.332 kWh/day) 411.317 kWh (28.249 kWh/day) -88.557 kWh (-6.082 kWh/day)
  - This Year 3.234 MWh (19.535 kWh/day) 2.981 MWh (18.007 kWh/day) -0.253 MWh (-1.528 kWh/day)
Yesterday 25.437 kWh (1.060 kW) 24.398 kWh (1.017 kW) -1.039 kWh (-0.043 kW)
Last 7 Days 217.061 kWh (31.009 kWh/day) 223.488 kWh (31.927 kWh/day) 6.427 kWh (0.918 kWh/day)
Last 30 Days (05/16/2026) 895.621 kWh (29.854 kWh/day) 727.060 kWh (24.235 kWh/day) -168.561 kWh (-5.619 kWh/day)
Last One Year 6.638 MWh (18.186 kWh/day) 7.924 MWh (21.709 kWh/day) 1.286 MWh (3.523 kWh/day)
Lifetime Since PTO 38.800 MWh (17.552 kW/day) 42.492 MWh (19.222 kW/day) 3.692 MWh (1.670 kW/day)
Lifetime Since Install 38.834 MWh 43.072 MWh 4.238 MWh
Voltage/Current 251.8 V / 17.4 A 251.7 V / -0.2 A 251.8 V / -17.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/17/2020 21:39 (5.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.283 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.192 3.485 0.000 kW
0.001 kWh
0.000 kW
0.004 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.180 3.365
03 - 202224****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.190 3.324
04 - 202232****** IQ7+ [5] VCOP 0.000 0.002 0.001 0.188 3.166
05 - 202244****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.175 3.569
06 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.001 0.182 3.640
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.005 0.002 0.170 4.235 0.000 kW
0.005 kWh
0.000 kW
0.024 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.004 0.001 0.055 0.055
09 - 202217****** IQ7+ [5] VCOP 0.000 0.006 0.007 0.171 4.538
10 - 202244****** IQ7+M [5] VCOP 0.000 0.006 0.008 0.174 4.491
11 - 202224****** IQ7+M [5] VCOP 0.000 0.005 0.005 0.170 4.157
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.016 0.050 0.192 1.785 0.000 kW
0.064 kWh
0.000 kW
0.255 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.014 0.040 0.193 1.956
14 - 202216****** IQ7+ [5] VCOP 0.000 0.012 0.036 0.197 1.958
15 - 202245****** IQ7+M [5] VCOP 0.000 0.050 0.130 0.193 1.902
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.49 V Current/Power 163.92 A (8.604 kW)
Remain Capacity/Energy 365.4 Ah (18.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Run Time 1h 22m to full Report Date 2020-12-17 23:27
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.49 V Cell (MIN/MAX) 3.275 V / 3.285 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 10d 3h 7m to empty
Remain Capacity/Energy 121.8 Ah (6.2 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 61.8 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-17 23:27
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V 3.280 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.281 V 3.281 V 3.282 V 3.282 V 3.283 V 3.284 V 3.284 V 3.285 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -