Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.546 kW
05/23/2026 12:45 (2187 days) Production Consumption NET Usage
Now 0.505 kW -0.041 kW -0.546 kW
Today 3.157 kWh (0.247 kW) 3.145 kWh (0.246 kW) -0.012 kWh (-0.001 kW)
  - This Week 158.529 kWh (24.269 kWh/day) 152.414 kWh (23.333 kWh/day) -6.115 kWh (-0.936 kWh/day)
  - This Month 560.345 kWh (24.869 kWh/day) 352.136 kWh (15.629 kWh/day) -208.209 kWh (-9.241 kWh/day)
  - This Year 2.513 MWh (17.634 kWh/day) 2.412 MWh (16.921 kWh/day) -0.102 MWh (-0.712 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 177.388 kWh (25.341 kWh/day) 158.221 kWh (22.603 kWh/day) -19.167 kWh (-2.738 kWh/day)
Last 30 Days (04/23/2026) 711.237 kWh (23.708 kWh/day) 420.291 kWh (14.010 kWh/day) -290.946 kWh (-9.698 kWh/day)
Last One Year 6.390 MWh (17.508 kWh/day) 7.786 MWh (21.333 kWh/day) 1.396 MWh (3.825 kWh/day)
Lifetime Since PTO 38.079 MWh (17.407 kW/day) 41.923 MWh (19.164 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.113 MWh 42.503 MWh 4.390 MWh
Voltage/Current 248.7 V / 2.0 A 248.8 V / -0.2 A 248.7 V / -2.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/06/2020 23:24 (9.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.215 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.230 1.005 0.279 3.270 0.000 kW
0.987 kWh
0.000 kW
5.921 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.227 0.967 0.282 3.188
03 - 202224****** IQ7+M [5] VCOP 0.000 0.229 0.942 0.294 3.167
04 - 202232****** IQ7+ [5] VCOP 0.000 0.224 0.883 0.291 3.017
05 - 202244****** IQ7+M [5] VCOP 0.000 0.231 1.064 0.291 3.400
06 - 202245****** IQ7+M [5] VCOP 0.000 0.229 1.060 0.279 3.385
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 1.331 0.326 3.883 0.000 kW
1.339 kWh
0.000 kW
6.697 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.172 0.335 3.460
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 1.448 0.344 4.140
10 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.427 0.345 4.135
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.320 0.346 3.847
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.088 0.347 0.190 1.810 0.000 kW
0.399 kWh
0.000 kW
1.597 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.092 0.425 0.194 1.963
14 - 202216****** IQ7+ [5] VCOP 0.000 0.092 0.419 0.196 1.957
15 - 202245****** IQ7+M [5] VCOP 0.000 0.089 0.405 0.192 1.909
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.