| Date Offset [+30][+10][+05][+01][-01][-05][-10][-30] |
|---|
| Exporting to grid by 0.438 kW | |||
|---|---|---|---|
| 05/23/2026 12:46 (2187 days) | Production | Consumption | NET Usage |
| Now | 0.488 kW | 0.050 kW | -0.438 kW |
| Today | 3.166 kWh (0.248 kW) | 3.144 kWh (0.246 kW) | -0.022 kWh (-0.002 kW) |
| - This Week | 158.538 kWh (24.268 kWh/day) | 152.413 kWh (23.330 kWh/day) | -6.125 kWh (-0.938 kWh/day) |
| - This Month | 560.354 kWh (24.869 kWh/day) | 352.135 kWh (15.628 kWh/day) | -208.219 kWh (-9.241 kWh/day) |
| - This Year | 2.513 MWh (17.634 kWh/day) | 2.412 MWh (16.921 kWh/day) | -0.102 MWh (-0.712 kWh/day) |
| Yesterday | 29.595 kWh (1.233 kW) | 5.105 kWh (0.213 kW) | -24.490 kWh (-1.020 kW) |
| Last 7 Days | 177.324 kWh (25.332 kWh/day) | 158.224 kWh (22.603 kWh/day) | -19.100 kWh (-2.729 kWh/day) |
| Last 30 Days (04/23/2026) | 711.207 kWh (23.707 kWh/day) | 420.288 kWh (14.010 kWh/day) | -290.919 kWh (-9.697 kWh/day) |
| Last One Year | 6.390 MWh (17.508 kWh/day) | 7.786 MWh (21.333 kWh/day) | 1.396 MWh (3.825 kWh/day) |
| Lifetime Since PTO | 38.079 MWh (17.407 kW/day) | 41.923 MWh (19.164 kW/day) | 3.844 MWh (1.757 kW/day) |
| Lifetime Since Install | 38.113 MWh | 42.503 MWh | 4.390 MWh |
| Voltage/Current | 249.0 V / 2.0 A | 248.9 V / 0.2 A | 249.0 V / -1.8 A |
|
|||
| Micro-inverters [pcu_num:0, pcu_level:0] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 12/07/2020 21:43 (9.1 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.000 kW (0.000 kW/panel) | Today Energy | 11.042 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.243 | 0.773 | 1.005 | 3.292 | 0.000 kW 0.753 kWh |
0.000 kW 4.516 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.238 | 0.746 | 0.967 | 3.202 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.244 | 0.725 | 0.942 | 3.170 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.242 | 0.688 | 0.883 | 3.011 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.242 | 0.793 | 1.064 | 3.427 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.241 | 0.790 | 1.060 | 3.421 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.292 | 0.995 | 1.331 | 3.973 | 0.000 kW 1.007 kWh |
0.000 kW 5.035 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 0.937 | 1.172 | 3.538 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.297 | 1.047 | 1.448 | 4.247 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.046 | 1.427 | 4.222 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.295 | 1.011 | 1.320 | 3.930 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.101 | 0.346 | 0.347 | 1.781 | 0.000 kW 0.373 kWh |
0.000 kW 1.491 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.117 | 0.386 | 0.425 | 1.939 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.114 | 0.384 | 0.419 | 1.935 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.116 | 0.376 | 0.405 | 1.887 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 kW 0.000 kWh |
0.000 kW 0.000 kWh |
| 17 - 122214****** | IQ7PD | [4] VCOP | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | |||
|
||||||||||