Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.529 kW
12/21/2025 16:00 (2034 days) Production Consumption NET Usage
Now 0.294 kW 0.823 kW 0.529 kW
Today 9.551 kWh (0.596 kW) 8.725 kWh (0.545 kW) -0.826 kWh (-0.052 kW)
  - This Week 9.551 kWh (14.309 kWh/day) 8.725 kWh (13.071 kWh/day) -0.826 kWh (-1.237 kWh/day)
  - This Month 184.457 kWh (8.925 kWh/day) 432.006 kWh (20.903 kWh/day) 247.549 kWh (11.978 kWh/day)
  - This Year 6.053 MWh (17.068 kWh/day) 7.348 MWh (20.719 kWh/day) 1.295 MWh (3.651 kWh/day)
Yesterday 12.220 kWh (0.509 kW) 17.015 kWh (0.709 kW) 4.795 kWh (0.200 kW)
Last 7 Days 54.155 kWh (7.736 kWh/day) 162.008 kWh (23.142 kWh/day) 107.853 kWh (15.406 kWh/day)
Last 30 Days 254.381 kWh (8.479 kWh/day) 620.587 kWh (20.686 kWh/day) 366.206 kWh (12.207 kWh/day)
Last One Year 6.114 MWh (16.749 kWh/day) 7.595 MWh (20.809 kWh/day) 1.482 MWh (4.059 kWh/day)
Lifetime Since PTO 35.504 MWh (17.449 kW/day) 39.301 MWh (19.315 kW/day) 3.797 MWh (1.866 kW/day)
Lifetime Since Install 35.538 MWh 39.881 MWh 4.343 MWh
Voltage/Current 250.6 V / 1.2 A 250.5 V / 3.3 A 250.6 V / 2.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/19/2020 23:23 (14.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.995 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 2.107 2.298 13.408 0.000 kW
2.028 kWh
0.000 kW
12.166 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.032 2.216 13.046
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.040 2.221 13.099
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.062 2.245 13.143
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.875 2.034 12.253
06 - 202245****** IQ7+M [5] VCOP 0.000 0.293 2.051 2.230 13.140
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.872 2.033 11.995 0.000 kW
1.923 kWh
0.000 kW
9.616 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.938 2.102 12.558
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.902 2.051 12.236
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.954 2.104 12.637
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.950 2.108 12.651
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.263 2.084 2.088 12.759 0.000 kW
2.053 kWh
0.000 kW
8.213 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.264 2.011 2.012 12.267
14 - 202216****** IQ7+ [5] VCOP 0.000 0.265 2.074 2.092 12.747
15 - 202245****** IQ7+M [5] VCOP 0.000 0.260 2.044 2.053 12.533
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.34 V Current/Power 163.40 A (8.552 kW)
Remain Capacity/Energy 204.9 Ah (10.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 35.5 % State Of Health 96.2 %
Run Time 2h 16m to full Report Date 2020-07-19 23:16
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.34 V Cell (MIN/MAX) 3.265 V / 3.277 V (0.012 V)
Current/Power -0.58 A (-30 W) Runtime 4d 20h 57m to empty
Remain Capacity/Energy 68.3 Ah (3.5 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 35.5 % State Of Health 96.2 %
Temperature 26.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-19 23:16
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.265 V 3.265 V 3.267 V 3.267 V 3.270 V 3.267 V 3.270 V 3.271 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.271 V 3.270 V 3.273 V 3.271 V 3.275 V 3.275 V 3.276 V 3.277 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -