Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.327 kW
04/07/2026 17:03 (2141 days) Production Consumption NET Usage
Now 2.949 kW 0.622 kW -2.327 kW
Today 30.673 kWh (1.797 kW) 9.812 kWh (0.575 kW) -20.861 kWh (-1.222 kW)
  - This Week 66.591 kWh (24.562 kWh/day) 34.513 kWh (12.730 kWh/day) -32.078 kWh (-11.832 kWh/day)
  - This Month 119.196 kWh (17.761 kWh/day) 95.572 kWh (14.241 kWh/day) -23.624 kWh (-3.520 kWh/day)
  - This Year 1.349 MWh (13.945 kWh/day) 1.661 MWh (17.174 kWh/day) 0.312 MWh (3.229 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 120.968 kWh (17.281 kWh/day) 100.295 kWh (14.328 kWh/day) -20.673 kWh (-2.953 kWh/day)
Last 30 Days (03/08/2026) 610.768 kWh (20.359 kWh/day) 446.793 kWh (14.893 kWh/day) -163.975 kWh (-5.466 kWh/day)
Last One Year 6.156 MWh (16.865 kWh/day) 7.832 MWh (21.457 kWh/day) 1.676 MWh (4.592 kWh/day)
Lifetime Since PTO 36.914 MWh (17.236 kW/day) 41.172 MWh (19.224 kW/day) 4.257 MWh (1.988 kW/day)
Lifetime Since Install 36.948 MWh 41.752 MWh 4.803 MWh
Voltage/Current 251.9 V / 11.7 A 252.1 V / 2.5 A 252.0 V / -9.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/20/2020 23:19 (9.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.376 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.208 1.041 0.933 5.231 0.000 kW
1.023 kWh
0.000 kW
6.140 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.206 1.012 0.916 5.211
03 - 202224****** IQ7+M [5] VCOP 0.000 0.210 1.002 0.917 5.236
04 - 202232****** IQ7+ [5] VCOP 0.000 0.209 0.973 0.881 5.065
05 - 202244****** IQ7+M [5] VCOP 0.000 0.211 1.061 0.925 5.158
06 - 202245****** IQ7+M [5] VCOP 0.000 0.208 1.052 0.923 4.982
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.266 1.252 1.072 5.958 0.000 kW
1.263 kWh
0.000 kW
6.316 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.113 1.008 5.455
09 - 202217****** IQ7+ [5] VCOP 0.000 0.265 1.349 1.149 6.501
10 - 202244****** IQ7+M [5] VCOP 0.000 0.265 1.341 1.145 6.436
11 - 202224****** IQ7+M [5] VCOP 0.000 0.265 1.263 1.096 6.101
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.102 0.435 0.503 2.886 0.000 kW
0.480 kWh
0.000 kW
1.920 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.102 0.502 0.539 3.139
14 - 202216****** IQ7+ [5] VCOP 0.000 0.103 0.499 0.537 3.063
15 - 202245****** IQ7+M [5] VCOP 0.000 0.100 0.484 0.524 3.035
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.37 V Current/Power 163.55 A (8.566 kW)
Remain Capacity/Energy 242.4 Ah (12.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 41.0 % State Of Health 98.5 %
Run Time 2h 7m to full Report Date 2020-11-20 23:26
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.37 V Cell (MIN/MAX) 3.268 V / 3.278 V (0.010 V)
Current/Power -0.47 A (-24 W) Runtime 7d 2h 27m to empty
Remain Capacity/Energy 80.8 Ah (4.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 41.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-20 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.268 V 3.268 V 3.270 V 3.270 V 3.271 V 3.271 V 3.272 V 3.273 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.274 V 3.273 V 3.275 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -