Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.334 kW
07/12/2025 08:34 (1872 days) Production Consumption NET Usage
Now 1.017 kW 5.351 kW 4.334 kW
Today 1.353 kWh (0.157 kW) 10.728 kWh (1.247 kW) 9.375 kWh (1.090 kW)
  - This Week 144.094 kWh (22.662 kWh/day) 297.386 kWh (46.770 kWh/day) 153.292 kWh (24.108 kWh/day)
  - This Month 273.803 kWh (24.106 kWh/day) 466.112 kWh (41.038 kWh/day) 192.309 kWh (16.931 kWh/day)
  - This Year 3.304 MWh (17.174 kWh/day) 3.593 MWh (18.681 kWh/day) 0.290 MWh (1.507 kWh/day)
Yesterday 27.044 kWh (1.128 kW) 64.693 kWh (2.699 kW) 37.649 kWh (1.571 kW)
Last 7 Days 173.467 kWh (24.784 kWh/day) 313.220 kWh (44.751 kWh/day) 139.753 kWh (19.967 kWh/day)
Last 30 Days 653.855 kWh (21.796 kWh/day) 1035.542 kWh (34.519 kWh/day) 381.687 kWh (12.723 kWh/day)
Last One Year 6.268 MWh (17.172 kWh/day) 6.518 MWh (17.856 kWh/day) 0.250 MWh (0.685 kWh/day)
Lifetime Since PTO 32.754 MWh (17.494 kW/day) 35.545 MWh (18.984 kW/day) 2.791 MWh (1.491 kW/day)
Lifetime Since Install 32.788 MWh 36.125 MWh 3.337 MWh
Voltage/Current 246.9 V / 4.1 A 246.9 V / 21.7 A 246.9 V / 17.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/02/2020 20:48 (14.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.666 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.258 1.309 2.075 9.365 0.000 kW
1.290 kWh
0.000 kW
7.739 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.286 1.987 9.117
03 - 202224****** IQ7+M [5] VCOP 0.000 0.258 1.307 1.966 9.127
04 - 202232****** IQ7+ [5] VCOP 0.000 0.258 1.291 1.988 9.159
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.261 1.765 8.507
06 - 202245****** IQ7+M [5] VCOP 0.000 0.255 1.286 2.024 9.111
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 1.183 1.814 8.295 0.000 kW
1.215 kWh
0.000 kW
6.073 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.211 1.869 8.626
09 - 202217****** IQ7+ [5] VCOP 0.000 0.273 1.216 1.861 8.531
10 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.235 1.877 8.706
11 - 202224****** IQ7+M [5] VCOP 0.000 0.275 1.226 1.877 8.713
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.201 1.214 2.227 9.237 0.000 kW
1.213 kWh
0.000 kW
4.854 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.202 1.196 2.150 8.954
14 - 202216****** IQ7+ [5] VCOP 0.000 0.202 1.230 2.211 9.193
15 - 202245****** IQ7+M [5] VCOP 0.000 0.199 1.214 2.175 9.069
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.04 V Current/Power 175.05 A (9.809 kW)
Remain Capacity/Energy 572.7 Ah (29.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.2 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-06-02 23:47
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.04 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.9 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.2 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-02 23:47
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.500 V 3.496 V 3.500 V 3.502 V 3.502 V 3.501 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.502 V 3.501 V 3.502 V 3.506 V 3.503 V 3.505 V 3.506 V 3.505 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -