Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.705 kW
04/07/2026 08:34 (2141 days) Production Consumption NET Usage
Now 1.066 kW 0.361 kW -0.705 kW
Today 3.322 kWh (0.387 kW) 4.178 kWh (0.487 kW) 0.856 kWh (0.100 kW)
  - This Week 39.240 kWh (16.646 kWh/day) 28.879 kWh (12.251 kWh/day) -10.361 kWh (-4.395 kWh/day)
  - This Month 91.845 kWh (14.447 kWh/day) 89.938 kWh (14.147 kWh/day) -1.907 kWh (-0.300 kWh/day)
  - This Year 1.321 MWh (13.712 kWh/day) 1.655 MWh (17.178 kWh/day) 0.334 MWh (3.466 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 109.439 kWh (15.634 kWh/day) 101.731 kWh (14.533 kWh/day) -7.708 kWh (-1.101 kWh/day)
Last 30 Days (03/08/2026) 593.569 kWh (19.786 kWh/day) 445.984 kWh (14.866 kWh/day) -147.585 kWh (-4.920 kWh/day)
Last One Year 6.131 MWh (16.796 kWh/day) 7.830 MWh (21.452 kWh/day) 1.699 MWh (4.656 kWh/day)
Lifetime Since PTO 36.887 MWh (17.226 kW/day) 41.166 MWh (19.224 kW/day) 4.279 MWh (1.998 kW/day)
Lifetime Since Install 36.921 MWh 41.746 MWh 4.825 MWh
Voltage/Current 248.8 V / 4.3 A 248.9 V / 1.5 A 248.9 V / -2.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/21/2021 23:23 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.215 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.285 1.996 2.038 9.104 0.000 kW
1.965 kWh
0.000 kW
11.789 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.966 1.995 8.891
03 - 202224****** IQ7+M [5] VCOP 0.000 0.286 2.011 2.033 9.102
04 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.016 2.025 9.066
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.906 1.936 8.666
06 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.893 1.926 8.679
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 2.084 2.099 9.155 0.000 kW
2.068 kWh
0.000 kW
10.342 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.942 1.936 8.534
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 2.076 2.092 9.208
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 2.124 2.142 9.380
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.116 2.137 9.328
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.220 1.536 1.531 7.122 0.000 kW
1.521 kWh
0.000 kW
6.084 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.217 1.487 1.479 6.957
14 - 202216****** IQ7+ [5] VCOP 0.000 0.219 1.544 1.532 7.170
15 - 202245****** IQ7+M [5] VCOP 0.000 0.216 1.518 1.501 7.029
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 580.5 Ah (29.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.2 % State Of Health 98.5 %
Run Time 26d 21h 0m to empty Report Date 2021-03-21 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.25 V Cell (MIN/MAX) 3.323 V / 3.332 V (0.009 V)
Current/Power -0.40 A (-21 W) Runtime 20d 3h 45m to empty
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.2 % State Of Health 98.5 %
Temperature 22.0 °C Cycle 34
MOSFET CFET = ON, DFET = ON Reported 2021-03-21 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.325 V 3.323 V 3.324 V 3.325 V 3.326 V 3.327 V 3.328 V 3.328 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.329 V 3.329 V 3.330 V 3.331 V 3.331 V 3.332 V 3.332 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.