Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.784 kW
07/12/2025 09:15 (1872 days) Production Consumption NET Usage
Now 2.456 kW 1.672 kW -0.784 kW
Today 1.874 kWh (0.202 kW) 11.864 kWh (1.278 kW) 9.990 kWh (1.076 kW)
  - This Week 144.615 kWh (22.643 kWh/day) 298.522 kWh (46.740 kWh/day) 153.907 kWh (24.098 kWh/day)
  - This Month 274.324 kWh (24.092 kWh/day) 467.248 kWh (41.036 kWh/day) 192.924 kWh (16.943 kWh/day)
  - This Year 3.304 MWh (17.174 kWh/day) 3.594 MWh (18.684 kWh/day) 0.290 MWh (1.510 kWh/day)
Yesterday 27.044 kWh (1.128 kW) 64.693 kWh (2.699 kW) 37.649 kWh (1.571 kW)
Last 7 Days 173.467 kWh (24.784 kWh/day) 313.220 kWh (44.751 kWh/day) 139.753 kWh (19.967 kWh/day)
Last 30 Days 653.855 kWh (21.796 kWh/day) 1035.542 kWh (34.519 kWh/day) 381.687 kWh (12.723 kWh/day)
Last One Year 6.268 MWh (17.172 kWh/day) 6.518 MWh (17.856 kWh/day) 0.250 MWh (0.685 kWh/day)
Lifetime Since PTO 32.755 MWh (17.494 kW/day) 35.546 MWh (18.985 kW/day) 2.792 MWh (1.491 kW/day)
Lifetime Since Install 32.789 MWh 36.126 MWh 3.338 MWh
Voltage/Current 248.3 V / 9.9 A 248.1 V / 6.7 A 248.2 V / -3.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/16/2020 20:26 (14.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.694 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.653 1.862 12.175 0.000 kW
1.646 kWh
0.000 kW
9.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.638 1.848 11.863
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.667 1.862 11.908
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.657 1.857 11.946
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.617 1.802 11.110
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.642 1.852 11.947
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.543 1.719 10.788 0.000 kW
1.614 kWh
0.000 kW
8.072 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.634 1.799 11.261
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.596 1.750 11.010
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.653 1.809 11.348
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.646 1.815 11.357
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.289 1.444 1.755 11.987 0.000 kW
1.437 kWh
0.000 kW
5.748 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.292 1.395 1.700 11.564
14 - 202216****** IQ7+ [5] VCOP 0.000 0.292 1.465 1.761 11.969
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.444 1.745 11.782
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.47 V Current/Power 163.88 A (8.599 kW)
Remain Capacity/Energy 327.9 Ah (16.8 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 56.8 % State Of Health 96.2 %
Run Time 1h 31m to full Report Date 2020-07-16 23:33
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.47 V Cell (MIN/MAX) 3.274 V / 3.284 V (0.010 V)
Current/Power -0.57 A (-29 W) Runtime 8d 0h 46m to empty
Remain Capacity/Energy 109.3 Ah (5.6 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 56.8 % State Of Health 96.2 %
Temperature 25.0 °C Cycle 23
MOSFET CFET = ON, DFET = ON Reported 2020-07-16 23:33
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.274 V 3.275 V 3.276 V 3.276 V 3.277 V 3.278 V 3.278 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.281 V 3.282 V 3.282 V 3.283 V 3.284 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -