Exporting to grid by 0.520 kW
04/07/2026 08:20 (2141 days) Production Consumption NET Usage
Now 0.954 kW 0.434 kW -0.520 kW
Today 3.097 kWh (0.371 kW) 4.093 kWh (0.490 kW) 0.996 kWh (0.119 kW)
  - This Week 39.015 kWh (16.617 kWh/day) 28.794 kWh (12.264 kWh/day) -10.221 kWh (-4.353 kWh/day)
  - This Month 91.620 kWh (14.433 kWh/day) 89.853 kWh (14.155 kWh/day) -1.767 kWh (-0.278 kWh/day)
  - This Year 1.321 MWh (13.711 kWh/day) 1.655 MWh (17.179 kWh/day) 0.334 MWh (3.468 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 109.347 kWh (15.621 kWh/day) 101.709 kWh (14.530 kWh/day) -7.638 kWh (-1.091 kWh/day)
Last 30 Days (03/08/2026) 593.372 kWh (19.779 kWh/day) 445.969 kWh (14.866 kWh/day) -147.403 kWh (-4.913 kWh/day)
Last One Year 6.130 MWh (16.796 kWh/day) 7.830 MWh (21.452 kWh/day) 1.699 MWh (4.656 kWh/day)
Lifetime Since PTO 36.887 MWh (17.226 kW/day) 41.166 MWh (19.224 kW/day) 4.279 MWh (1.998 kW/day)
Lifetime Since Install 36.921 MWh 41.746 MWh 4.825 MWh
Voltage/Current 248.7 V / 3.8 A 248.6 V / 1.7 A 248.6 V / -2.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/03/2021 23:45 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.435 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.719 1.515 10.640 0.000 kW
0.703 kWh
0.000 kW
4.217 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.189 0.697 1.450 10.269
03 - 202224****** IQ7+M [5] VCOP 0.000 0.189 0.719 1.485 10.529
04 - 202232****** IQ7+ [5] VCOP 0.000 0.188 0.714 1.505 10.626
05 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.675 1.375 9.769
06 - 202245****** IQ7+M [5] VCOP 0.000 0.188 0.693 1.431 10.167
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.182 0.643 1.451 9.884 0.000 kW
0.647 kWh
0.000 kW
3.235 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.179 0.638 1.456 10.019
09 - 202217****** IQ7+ [5] VCOP 0.000 0.181 0.649 1.472 9.962
10 - 202244****** IQ7+M [5] VCOP 0.000 0.182 0.657 1.500 10.240
11 - 202224****** IQ7+M [5] VCOP 0.000 0.180 0.648 1.491 10.229
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.177 0.740 1.409 10.088 0.000 kW
0.746 kWh
0.000 kW
2.983 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.176 0.744 1.358 9.722
14 - 202216****** IQ7+ [5] VCOP 0.000 0.179 0.754 1.416 10.117
15 - 202245****** IQ7+M [5] VCOP 0.000 0.178 0.745 1.393 9.948
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.18 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 510.6 Ah (26.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.1 % State Of Health 100.0 %
Run Time 14d 4h 24m to empty Report Date 2021-05-03 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.