Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.096 kW
04/07/2026 07:36 (2141 days) Production Consumption NET Usage
Now 0.471 kW 0.567 kW 0.096 kW
Today 2.496 kWh (0.328 kW) 3.579 kWh (0.470 kW) 1.083 kWh (0.142 kW)
  - This Week 38.414 kWh (16.576 kWh/day) 28.280 kWh (12.203 kWh/day) -10.134 kWh (-4.373 kWh/day)
  - This Month 91.019 kWh (14.407 kWh/day) 89.339 kWh (14.141 kWh/day) -1.680 kWh (-0.266 kWh/day)
  - This Year 1.320 MWh (13.709 kWh/day) 1.655 MWh (17.179 kWh/day) 0.334 MWh (3.470 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 109.067 kWh (15.581 kWh/day) 101.468 kWh (14.495 kWh/day) -7.599 kWh (-1.086 kWh/day)
Last 30 Days (03/08/2026) 592.808 kWh (19.760 kWh/day) 445.621 kWh (14.854 kWh/day) -147.187 kWh (-4.906 kWh/day)
Last One Year 6.130 MWh (16.794 kWh/day) 7.830 MWh (21.452 kWh/day) 1.700 MWh (4.658 kWh/day)
Lifetime Since PTO 36.886 MWh (17.226 kW/day) 41.165 MWh (19.224 kW/day) 4.279 MWh (1.998 kW/day)
Lifetime Since Install 36.920 MWh 41.745 MWh 4.825 MWh
Voltage/Current 248.7 V / 1.9 A 248.6 V / 2.3 A 248.7 V / 0.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/11/2021 20:19 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.526 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.991 0.956 8.889 0.000 kW
1.897 kWh
0.000 kW
11.381 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.303 1.895 0.927 8.549
03 - 202224****** IQ7+M [5] VCOP 0.000 0.302 1.910 0.957 8.755
04 - 202232****** IQ7+ [5] VCOP 0.000 0.302 1.948 0.945 8.816
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.730 0.909 8.095
06 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.908 0.926 8.542
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.749 0.842 8.102 0.000 kW
1.771 kWh
0.000 kW
8.854 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 1.757 0.847 8.038
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.754 0.857 8.156
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.790 0.867 8.248
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.804 0.875 8.196
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.294 2.097 0.929 9.063 0.000 kW
2.073 kWh
0.000 kW
8.292 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.293 2.039 0.932 8.937
14 - 202216****** IQ7+ [5] VCOP 0.000 0.294 2.090 0.942 9.124
15 - 202245****** IQ7+M [5] VCOP 0.000 0.293 2.066 0.928 9.008
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 523.5 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.2 % State Of Health 100.0 %
Run Time 18d 4h 14m to empty Report Date 2021-05-11 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.