Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.084 kW
05/23/2026 05:01 (2187 days) Production Consumption NET Usage
Now 0.000 kW 0.084 kW 0.084 kW
Today 0.000 kWh (0.000 kW) 0.366 kWh (0.073 kW) 0.366 kWh (0.073 kW)
  - This Week 155.372 kWh (25.020 kWh/day) 149.635 kWh (24.096 kWh/day) -5.737 kWh (-0.924 kWh/day)
  - This Month 557.188 kWh (25.088 kWh/day) 349.357 kWh (15.730 kWh/day) -207.831 kWh (-9.358 kWh/day)
  - This Year 2.510 MWh (17.652 kWh/day) 2.409 MWh (16.940 kWh/day) -0.101 MWh (-0.711 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.506 kWh (22.358 kWh/day) -31.784 kWh (-4.541 kWh/day)
Last 30 Days (04/23/2026) 721.023 kWh (24.034 kWh/day) 420.774 kWh (14.026 kWh/day) -300.249 kWh (-10.008 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.787 MWh (21.335 kWh/day) 1.395 MWh (3.823 kWh/day)
Lifetime Since PTO 38.076 MWh (17.408 kW/day) 41.920 MWh (19.166 kW/day) 3.844 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 250.1 V / 0.0 A 250.1 V / 0.3 A 250.1 V / 0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/03/2021 23:58 (12.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.953 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.173 0.764 1.029 11.182 0.000 kW
0.747 kWh
0.000 kW
4.481 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.167 0.733 0.998 10.718
03 - 202224****** IQ7+M [0] ---- 0.000 0.174 0.770 1.039 10.823
04 - 202232****** IQ7+ [0] ---- 0.000 0.173 0.757 1.025 10.904
05 - 202244****** IQ7+M [0] ---- 0.000 0.167 0.726 0.993 9.918
06 - 202245****** IQ7+M [0] ---- 0.000 0.165 0.731 0.996 10.834
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.167 0.686 0.935 9.774 0.000 kW
0.687 kWh
0.000 kW
3.435 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.178 0.681 0.945 10.065
09 - 202217****** IQ7+ [0] ---- 0.000 0.173 0.690 0.943 9.987
10 - 202244****** IQ7+M [0] ---- 0.000 0.175 0.696 0.956 10.214
11 - 202224****** IQ7+M [0] ---- 0.000 0.170 0.683 0.948 10.199
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.169 0.755 0.986 11.133 0.000 kW
0.759 kWh
0.000 kW
3.036 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.170 0.757 0.975 10.797
14 - 202216****** IQ7+ [0] ---- 0.000 0.171 0.769 1.003 11.158
15 - 202245****** IQ7+M [0] ---- 0.000 0.171 0.755 0.985 10.980
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.70 V Current/Power -9.61 A (-0.506 kW)
Remain Capacity/Energy 345.0 Ah (17.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 57.5 % State Of Health 100.0 %
Run Time 1d 11h 54m to empty Report Date 2021-07-03 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.