Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.703 kW
07/12/2025 10:01 (1872 days) Production Consumption NET Usage
Now 3.117 kW 0.414 kW -2.703 kW
Today 3.879 kWh (0.386 kW) 12.431 kWh (1.236 kW) 8.552 kWh (0.850 kW)
  - This Week 146.620 kWh (22.842 kWh/day) 299.089 kWh (46.595 kWh/day) 152.469 kWh (23.753 kWh/day)
  - This Month 276.329 kWh (24.200 kWh/day) 467.815 kWh (40.970 kWh/day) 191.486 kWh (16.770 kWh/day)
  - This Year 3.306 MWh (17.182 kWh/day) 3.595 MWh (18.684 kWh/day) 0.289 MWh (1.502 kWh/day)
Yesterday 27.044 kWh (1.128 kW) 64.693 kWh (2.699 kW) 37.649 kWh (1.571 kW)
Last 7 Days 173.467 kWh (24.784 kWh/day) 313.220 kWh (44.751 kWh/day) 139.753 kWh (19.967 kWh/day)
Last 30 Days 653.855 kWh (21.796 kWh/day) 1035.542 kWh (34.519 kWh/day) 381.687 kWh (12.723 kWh/day)
Last One Year 6.268 MWh (17.172 kWh/day) 6.518 MWh (17.856 kWh/day) 0.250 MWh (0.685 kWh/day)
Lifetime Since PTO 32.757 MWh (17.494 kW/day) 35.547 MWh (18.985 kW/day) 2.790 MWh (1.490 kW/day)
Lifetime Since Install 32.791 MWh 36.127 MWh 3.336 MWh
Voltage/Current 249.7 V / 12.5 A 249.5 V / 1.7 A 249.6 V / -10.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/23/2020 23:45 (13.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.892 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.877 1.602 10.615 0.000 kW
1.862 kWh
0.000 kW
11.171 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.854 1.580 10.405
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.887 1.603 10.610
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.896 1.600 10.654
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.814 1.542 9.948
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.844 1.573 10.253
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.882 1.531 10.050 0.000 kW
1.894 kWh
0.000 kW
9.470 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.888 1.583 10.185
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.881 1.529 10.036
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.908 1.592 10.338
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.911 1.604 10.376
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.266 1.578 1.342 9.653 0.000 kW
1.563 kWh
0.000 kW
6.250 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.268 1.507 1.312 9.279
14 - 202216****** IQ7+ [5] VCOP 0.000 0.269 1.592 1.347 9.667
15 - 202245****** IQ7+M [5] VCOP 0.000 0.265 1.572 1.325 9.504
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.10 V Current/Power 162.65 A (8.474 kW)
Remain Capacity/Energy 176.7 Ah (9.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 30.6 % State Of Health 96.2 %
Run Time 2h 27m to full Report Date 2020-08-23 23:40
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.10 V Cell (MIN/MAX) 3.249 V / 3.262 V (0.013 V)
Current/Power -0.53 A (-27 W) Runtime 4d 15h 20m to empty
Remain Capacity/Energy 58.9 Ah (3.0 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 30.6 % State Of Health 96.2 %
Temperature 26.0 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-23 23:40
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.249 V 3.250 V 3.251 V 3.251 V 3.256 V 3.253 V 3.256 V 3.256 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.256 V 3.255 V 3.258 V 3.257 V 3.259 V 3.260 V 3.262 V 3.262 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -