Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.038 kW
04/07/2026 04:55 (2141 days) Production Consumption NET Usage
Now 0.317 kW 0.279 kW -0.038 kW
Today 1.564 kWh (0.317 kW) 2.346 kWh (0.475 kW) 0.782 kWh (0.158 kW)
  - This Week 37.482 kWh (16.994 kWh/day) 27.047 kWh (12.263 kWh/day) -10.435 kWh (-4.731 kWh/day)
  - This Month 90.087 kWh (14.517 kWh/day) 88.106 kWh (14.198 kWh/day) -1.981 kWh (-0.319 kWh/day)
  - This Year 1.319 MWh (13.715 kWh/day) 1.653 MWh (17.187 kWh/day) 0.334 MWh (3.471 kWh/day)
Yesterday 31.457 kWh (1.310 kW) 5.096 kWh (0.212 kW) -26.361 kWh (-1.098 kW)
Last 7 Days 108.169 kWh (15.453 kWh/day) 101.239 kWh (14.463 kWh/day) -6.930 kWh (-0.990 kWh/day)
Last 30 Days (03/08/2026) 591.876 kWh (19.729 kWh/day) 445.632 kWh (14.854 kWh/day) -146.244 kWh (-4.875 kWh/day)
Last One Year 6.129 MWh (16.792 kWh/day) 7.831 MWh (21.455 kWh/day) 1.702 MWh (4.663 kWh/day)
Lifetime Since PTO 36.885 MWh (17.226 kW/day) 41.164 MWh (19.225 kW/day) 4.279 MWh (1.998 kW/day)
Lifetime Since Install 36.919 MWh 41.744 MWh 4.825 MWh
Voltage/Current 249.5 V / 1.3 A 249.5 V / 1.1 A 249.5 V / -0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/29/2021 20:24 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.518 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.078 0.386 1.276 12.342 0.000 kW
0.375 kWh
0.000 kW
2.251 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.076 0.368 1.231 11.939
03 - 202224****** IQ7+M [0] ---- 0.000 0.078 0.386 1.241 12.062
04 - 202232****** IQ7+ [0] ---- 0.000 0.078 0.382 1.250 12.139
05 - 202244****** IQ7+M [0] ---- 0.000 0.075 0.358 1.056 11.205
06 - 202245****** IQ7+M [0] ---- 0.000 0.076 0.371 1.236 11.993
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.070 0.344 1.094 11.254 0.000 kW
0.345 kWh
0.000 kW
1.727 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.070 0.340 1.078 11.314
09 - 202217****** IQ7+ [0] ---- 0.000 0.071 0.347 1.097 11.360
10 - 202244****** IQ7+M [0] ---- 0.000 0.072 0.351 1.105 11.493
11 - 202224****** IQ7+M [0] ---- 0.000 0.070 0.346 1.096 11.497
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.078 0.382 1.472 12.270 0.000 kW
0.385 kWh
0.000 kW
1.540 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.078 0.384 1.469 11.970
14 - 202216****** IQ7+ [0] ---- 0.000 0.081 0.390 1.472 12.272
15 - 202245****** IQ7+M [0] ---- 0.000 0.078 0.385 1.463 12.143
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.19 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 524.7 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 14d 13h 48m to empty Report Date 2021-05-29 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.