Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.065 kW
05/23/2026 03:14 (2187 days) Production Consumption NET Usage
Now 0.000 kW -0.065 kW -0.065 kW
Today 0.000 kWh (0.000 kW) 0.361 kWh (0.111 kW) 0.361 kWh (0.111 kW)
  - This Week 155.372 kWh (25.323 kWh/day) 149.630 kWh (24.387 kWh/day) -5.742 kWh (-0.936 kWh/day)
  - This Month 557.188 kWh (25.172 kWh/day) 349.352 kWh (15.783 kWh/day) -207.836 kWh (-9.389 kWh/day)
  - This Year 2.510 MWh (17.661 kWh/day) 2.409 MWh (16.949 kWh/day) -0.101 MWh (-0.712 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 188.290 kWh (26.899 kWh/day) 156.393 kWh (22.342 kWh/day) -31.897 kWh (-4.557 kWh/day)
Last 30 Days (04/23/2026) 721.023 kWh (24.034 kWh/day) 420.712 kWh (14.024 kWh/day) -300.311 kWh (-10.010 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.788 MWh (21.337 kWh/day) 1.396 MWh (3.825 kWh/day)
Lifetime Since PTO 38.076 MWh (17.409 kW/day) 41.920 MWh (19.167 kW/day) 3.844 MWh (1.758 kW/day)
Lifetime Since Install 38.110 MWh 42.500 MWh 4.390 MWh
Voltage/Current 250.2 V / 0.0 A 250.3 V / -0.3 A 250.2 V / -0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/17/2021 23:17 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.791 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.298 1.971 9.085 0.000 kW
1.252 kWh
0.000 kW
7.512 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.262 1.888 8.776
03 - 202224****** IQ7+M [0] ---- 0.000 0.299 1.277 1.910 8.947
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.296 1.931 8.974
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.112 1.756 8.465
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.267 1.898 8.804
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.293 1.137 1.805 8.409 0.000 kW
1.138 kWh
0.000 kW
5.691 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.130 1.791 8.411
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 1.143 1.801 8.458
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.143 1.805 8.537
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.138 1.804 8.527
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.286 1.399 1.944 8.663 0.000 kW
1.397 kWh
0.000 kW
5.588 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.286 1.385 1.894 8.491
14 - 202216****** IQ7+ [0] ---- 0.000 0.286 1.411 1.943 8.747
15 - 202245****** IQ7+M [0] ---- 0.000 0.282 1.392 1.918 8.636
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.23 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 496.8 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.8 % State Of Health 100.0 %
Run Time 13d 19h 12m to empty Report Date 2021-07-17 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.