Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.970 kW
07/12/2025 17:27 (1872 days) Production Consumption NET Usage
Now 0.761 kW 2.731 kW 1.970 kW
Today 23.086 kWh (1.320 kW) 28.769 kWh (1.645 kW) 5.683 kWh (0.325 kW)
  - This Week 165.827 kWh (24.645 kWh/day) 315.427 kWh (46.879 kWh/day) 149.600 kWh (22.234 kWh/day)
  - This Month 295.536 kWh (25.199 kWh/day) 484.153 kWh (41.281 kWh/day) 188.617 kWh (16.082 kWh/day)
  - This Year 3.325 MWh (17.254 kWh/day) 3.611 MWh (18.738 kWh/day) 0.286 MWh (1.485 kWh/day)
Yesterday 27.044 kWh (1.128 kW) 64.693 kWh (2.699 kW) 37.649 kWh (1.571 kW)
Last 7 Days 173.467 kWh (24.784 kWh/day) 313.220 kWh (44.751 kWh/day) 139.753 kWh (19.967 kWh/day)
Last 30 Days 653.855 kWh (21.796 kWh/day) 1035.542 kWh (34.519 kWh/day) 381.687 kWh (12.723 kWh/day)
Last One Year 6.268 MWh (17.172 kWh/day) 6.518 MWh (17.856 kWh/day) 0.250 MWh (0.685 kWh/day)
Lifetime Since PTO 32.776 MWh (17.502 kW/day) 35.563 MWh (18.990 kW/day) 2.787 MWh (1.488 kW/day)
Lifetime Since Install 32.810 MWh 36.143 MWh 3.333 MWh
Voltage/Current 247.5 V / 3.1 A 247.5 V / 11.0 A 247.5 V / 8.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/23/2020 22:57 (11.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.562 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 1.739 1.799 11.418 0.000 kW
1.715 kWh
0.000 kW
10.289 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.720 1.783 11.324
03 - 202224****** IQ7+M [5] VCOP 0.000 0.257 1.743 1.808 11.504
04 - 202232****** IQ7+ [5] VCOP 0.000 0.256 1.730 1.793 11.435
05 - 202244****** IQ7+M [5] VCOP 0.000 0.257 1.687 1.748 11.102
06 - 202245****** IQ7+M [5] VCOP 0.000 0.255 1.669 1.733 11.048
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.285 1.823 1.894 11.800 0.000 kW
1.814 kWh
0.000 kW
9.068 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.695 1.779 11.219
09 - 202217****** IQ7+ [5] VCOP 0.000 0.285 1.841 1.910 11.864
10 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.858 1.924 11.984
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.851 1.913 11.915
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.194 1.316 1.376 9.102 0.000 kW
1.301 kWh
0.000 kW
5.204 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.194 1.286 1.336 8.906
14 - 202216****** IQ7+ [5] VCOP 0.000 0.193 1.313 1.376 9.149
15 - 202245****** IQ7+M [5] VCOP 0.000 0.190 1.289 1.350 9.002
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.02 V Current/Power 175.05 A (9.807 kW)
Remain Capacity/Energy 573.0 Ah (29.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.0 % State Of Health 98.5 %
Run Time 6m to full Report Date 2020-09-23 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.506 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.0 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 97.0 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-23 23:52
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.501 V 3.495 V 3.501 V 3.504 V 3.499 V 3.501 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.499 V 3.501 V 3.501 V 3.501 V 3.503 V 3.506 V 3.506 V 3.504 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -