Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.040 kW
04/09/2026 06:15 (2143 days) Production Consumption NET Usage
Now 0.317 kW 0.357 kW 0.040 kW
Today 1.984 kWh (0.317 kW) 2.879 kWh (0.460 kW) 0.895 kWh (0.143 kW)
  - This Week 112.988 kWh (26.517 kWh/day) 59.511 kWh (13.966 kWh/day) -53.477 kWh (-12.550 kWh/day)
  - This Month 165.593 kWh (20.045 kWh/day) 120.570 kWh (14.595 kWh/day) -45.023 kWh (-5.450 kWh/day)
  - This Year 1.395 MWh (14.197 kWh/day) 1.686 MWh (17.157 kWh/day) 0.291 MWh (2.960 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 152.884 kWh (21.841 kWh/day) 101.007 kWh (14.430 kWh/day) -51.877 kWh (-7.411 kWh/day)
Last 30 Days (03/10/2026) 631.201 kWh (21.040 kWh/day) 449.818 kWh (14.994 kWh/day) -181.383 kWh (-6.046 kWh/day)
Last One Year 6.172 MWh (16.909 kWh/day) 7.833 MWh (21.459 kWh/day) 1.661 MWh (4.550 kWh/day)
Lifetime Since PTO 36.961 MWh (17.245 kW/day) 41.197 MWh (19.221 kW/day) 4.236 MWh (1.976 kW/day)
Lifetime Since Install 36.995 MWh 41.777 MWh 4.782 MWh
Voltage/Current 250.3 V / 1.3 A 250.4 V / 1.4 A 250.3 V / 0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/07/2021 20:33 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.634 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.022 1.940 10.274 0.000 kW
1.924 kWh
0.000 kW
11.542 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.289 1.926 1.856 9.837
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.933 1.871 9.957
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.960 1.884 10.015
05 - 202244****** IQ7+M [0] ---- 0.000 0.292 1.756 1.698 9.124
06 - 202245****** IQ7+M [0] ---- 0.000 0.287 1.945 1.875 9.948
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 1.770 1.735 9.059 0.000 kW
1.806 kWh
0.000 kW
9.030 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.803 1.724 9.198
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 1.798 1.742 9.170
10 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.828 1.743 9.312
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.831 1.740 9.257
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.258 2.038 1.916 10.370 0.000 kW
2.016 kWh
0.000 kW
8.062 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.258 1.979 1.881 10.148
14 - 202216****** IQ7+ [0] ---- 0.000 0.258 2.037 1.919 10.432
15 - 202245****** IQ7+M [0] ---- 0.000 0.260 2.009 1.889 10.260
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 525.9 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.7 % State Of Health 100.0 %
Run Time 18d 6h 14m to empty Report Date 2021-07-07 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.