Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.255 kW
07/13/2025 03:09 (1873 days) Production Consumption NET Usage
Now 0.000 kW 0.255 kW 0.255 kW
Today 0.000 kWh (0.000 kW) 2.546 kWh (0.798 kW) 2.546 kWh (0.798 kW)
  - This Week 0.000 kWh (0.000 kWh/day) 2.546 kWh (19.162 kWh/day) 2.546 kWh (19.162 kWh/day)
  - This Month 297.078 kWh (24.486 kWh/day) 499.404 kWh (41.162 kWh/day) 202.326 kWh (16.676 kWh/day)
  - This Year 3.327 MWh (17.225 kWh/day) 3.627 MWh (18.778 kWh/day) 0.300 MWh (1.553 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.778 MWh (17.499 kW/day) 35.579 MWh (18.994 kW/day) 2.801 MWh (1.495 kW/day)
Lifetime Since Install 32.812 MWh 36.159 MWh 3.347 MWh
Voltage/Current 251.7 V / 0.0 A 251.8 V / 1.0 A 251.8 V / 1.0 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/20/2020 22:34 (10.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.591 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.222 0.591 0.895 7.432 0.000 kW
0.588 kWh
0.000 kW
3.527 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.222 0.583 0.884 7.293
03 - 202224****** IQ7+M [0] ---- 0.000 0.233 0.593 0.898 7.372
04 - 202232****** IQ7+ [0] ---- 0.000 0.223 0.584 0.889 7.295
05 - 202244****** IQ7+M [0] ---- 0.000 0.225 0.588 0.884 7.337
06 - 202245****** IQ7+M [0] ---- 0.000 0.229 0.588 0.887 7.337
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.277 0.699 0.915 7.985 0.000 kW
0.707 kWh
0.000 kW
3.533 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.278 0.691 0.826 7.381
09 - 202217****** IQ7+ [0] ---- 0.000 0.287 0.712 0.946 8.244
10 - 202244****** IQ7+M [0] ---- 0.000 0.278 0.719 0.951 8.344
11 - 202224****** IQ7+M [0] ---- 0.000 0.275 0.713 0.929 8.202
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.108 0.374 0.740 4.925 0.000 kW
0.383 kWh
0.000 kW
1.531 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.121 0.382 0.740 4.982
14 - 202216****** IQ7+ [0] ---- 0.000 0.122 0.392 0.749 5.086
15 - 202245****** IQ7+M [0] ---- 0.000 0.118 0.383 0.739 5.000
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.02 V Current/Power 175.09 A (9.809 kW)
Remain Capacity/Energy 590.7 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-20 23:26
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power -0.01 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.9 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-20 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.499 V 3.501 V 3.501 V 3.503 V 3.498 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.497 V 3.501 V 3.500 V 3.501 V 3.506 V 3.502 V 3.503 V 3.503 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -