Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.472 kW
12/22/2025 09:02 (2035 days) Production Consumption NET Usage
Now 0.783 kW 0.311 kW -0.472 kW
Today 0.426 kWh (0.047 kW) 5.053 kWh (0.559 kW) 4.627 kWh (0.512 kW)
  - This Week 10.023 kWh (7.279 kWh/day) 21.787 kWh (15.822 kWh/day) 11.764 kWh (8.543 kWh/day)
  - This Month 184.929 kWh (8.651 kWh/day) 445.068 kWh (20.820 kWh/day) 260.139 kWh (12.169 kWh/day)
  - This Year 6.054 MWh (17.035 kWh/day) 7.361 MWh (20.714 kWh/day) 1.307 MWh (3.679 kWh/day)
Yesterday 9.597 kWh (0.400 kW) 16.734 kWh (0.697 kW) 7.137 kWh (0.297 kW)
Last 7 Days 63.452 kWh (9.064 kWh/day) 161.752 kWh (23.106 kWh/day) 98.300 kWh (14.042 kWh/day)
Last 30 Days 259.643 kWh (8.655 kWh/day) 622.166 kWh (20.739 kWh/day) 362.523 kWh (12.084 kWh/day)
Last One Year 6.123 MWh (16.774 kWh/day) 7.596 MWh (20.811 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 35.505 MWh (17.443 kW/day) 39.314 MWh (19.315 kW/day) 3.809 MWh (1.872 kW/day)
Lifetime Since Install 35.539 MWh 39.894 MWh 4.355 MWh
Voltage/Current 249.1 V / 3.1 A 249.0 V / 1.2 A 249.0 V / -1.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/03/2021 22:45 (12.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.436 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.186 0.719 1.508 10.625 0.000 kW
0.703 kWh
0.000 kW
4.217 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.182 0.697 1.442 10.251
03 - 202224****** IQ7+M [5] VCOP 0.000 0.186 0.719 1.477 10.516
04 - 202232****** IQ7+ [5] VCOP 0.000 0.184 0.714 1.498 10.611
05 - 202244****** IQ7+M [5] VCOP 0.000 0.180 0.675 1.367 9.750
06 - 202245****** IQ7+M [5] VCOP 0.000 0.180 0.693 1.424 10.147
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.177 0.643 1.443 9.866 0.000 kW
0.647 kWh
0.000 kW
3.234 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.177 0.638 1.448 10.005
09 - 202217****** IQ7+ [5] VCOP 0.000 0.179 0.649 1.464 9.949
10 - 202244****** IQ7+M [5] VCOP 0.000 0.179 0.656 1.492 10.223
11 - 202224****** IQ7+M [5] VCOP 0.000 0.178 0.647 1.483 10.213
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.171 0.741 1.403 10.084 0.000 kW
0.746 kWh
0.000 kW
2.985 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.172 0.745 1.353 9.721
14 - 202216****** IQ7+ [5] VCOP 0.000 0.172 0.754 1.411 10.112
15 - 202245****** IQ7+M [5] VCOP 0.000 0.171 0.745 1.389 9.942
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.18 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 509.4 Ah (26.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.9 % State Of Health 100.0 %
Run Time 17d 16h 29m to empty Report Date 2021-05-03 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.30 A (-15 W) Runtime 23d 14h 0m to empty
Remain Capacity/Energy 169.8 Ah (8.7 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 84.9 % State Of Health 100.0 %
Temperature 20.5 °C Cycle 38
MOSFET CFET = ON, DFET = ON Reported 2021-05-03 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.322 V 3.323 V 3.323 V 3.325 V 3.325 V 3.326 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.327 V 3.328 V 3.329 V 3.330 V 3.330 V 3.331 V 3.331 V
pack voltage and current cell voltages
pack temperature
Voltage 53.16 V Cell (MIN/MAX) 3.322 V / 3.323 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 90.3 Ah (4.6 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 90.3 % State Of Health 100.0 %
Temperature 22.8 °C Cycle 4
MOSFET CFET = ON, DFET = ON Reported 2021-05-03 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.323 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature
Voltage 53.20 V Cell (MIN/MAX) 3.324 V / 3.325 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 21.1 °C Cycle 4
MOSFET CFET = ON, DFET = ON Reported 2021-05-03 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.324 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.325 V 3.325 V 3.325 V 3.325 V 3.324 V 3.325 V 3.324 V
pack voltage and current cell voltages
pack temperature
Voltage 53.15 V Cell (MIN/MAX) 3.322 V / 3.322 V (0.000 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.5 Ah (5.1 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 100.0 %
Temperature 20.6 °C Cycle 4
MOSFET CFET = ON, DFET = ON Reported 2021-05-03 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature
Voltage 53.17 V Cell (MIN/MAX) 3.322 V / 3.323 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 99.2 Ah (5.1 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 99.5 % State Of Health 99.7 %
Temperature 22.7 °C Cycle 4
MOSFET CFET = ON, DFET = ON Reported 2021-05-03 23:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.322 V 3.323 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V 3.322 V
pack voltage and current cell voltages
pack temperature