Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.947 kW
07/13/2025 10:18 (1873 days) Production Consumption NET Usage
Now 1.338 kW 0.391 kW -0.947 kW
Today 3.358 kWh (0.325 kW) 7.182 kWh (0.695 kW) 3.824 kWh (0.370 kW)
  - This Week 3.358 kWh (7.797 kWh/day) 7.182 kWh (16.676 kWh/day) 3.824 kWh (8.879 kWh/day)
  - This Month 300.436 kWh (24.169 kWh/day) 504.040 kWh (40.549 kWh/day) 203.604 kWh (16.379 kWh/day)
  - This Year 3.330 MWh (17.216 kWh/day) 3.631 MWh (18.773 kWh/day) 0.301 MWh (1.557 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.781 MWh (17.498 kW/day) 35.583 MWh (18.994 kW/day) 2.802 MWh (1.496 kW/day)
Lifetime Since Install 32.815 MWh 36.163 MWh 3.348 MWh
Voltage/Current 248.5 V / 5.4 A 248.6 V / 1.6 A 248.6 V / -3.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/28/2020 21:45 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.410 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.514 0.569 4.144 0.000 kW
0.508 kWh
0.000 kW
3.048 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.214 0.490 0.539 4.023
03 - 202224****** IQ7+M [5] VCOP 0.000 0.197 0.482 0.520 4.009
04 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.463 0.478 3.841
05 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.549 0.602 4.205
06 - 202245****** IQ7+M [5] VCOP 0.000 0.212 0.549 0.602 4.181
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 0.588 0.600 4.737 0.000 kW
0.581 kWh
0.000 kW
2.903 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.260 0.457 0.453 4.408
09 - 202217****** IQ7+ [5] VCOP 0.000 0.258 0.643 0.668 5.029
10 - 202244****** IQ7+M [5] VCOP 0.000 0.266 0.638 0.669 5.025
11 - 202224****** IQ7+M [5] VCOP 0.000 0.264 0.577 0.581 4.754
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.100 0.360 0.405 2.315 0.000 kW
0.365 kWh
0.000 kW
1.459 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.111 0.368 0.414 2.503
14 - 202216****** IQ7+ [5] VCOP 0.000 0.111 0.370 0.416 2.501
15 - 202245****** IQ7+M [5] VCOP 0.000 0.107 0.361 0.405 2.438
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.04 V Current/Power 178.17 A (10.162 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-28 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.04 V Cell (MIN/MAX) 3.555 V / 3.570 V (0.015 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-11-28 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.559 V 3.561 V 3.565 V 3.563 V 3.567 V 3.568 V 3.565 V 3.568 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.566 V 3.557 V 3.555 V 3.567 V 3.565 V 3.570 V 3.568 V 3.568 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -