Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.556 kW
07/13/2025 17:43 (1873 days) Production Consumption NET Usage
Now 2.386 kW 0.830 kW -1.556 kW
Today 19.150 kWh (1.079 kW) 22.284 kWh (1.255 kW) 3.134 kWh (0.177 kW)
  - This Week 19.150 kWh (25.891 kWh/day) 22.284 kWh (30.128 kWh/day) 3.134 kWh (4.237 kWh/day)
  - This Month 316.228 kWh (24.823 kWh/day) 519.142 kWh (40.751 kWh/day) 202.914 kWh (15.928 kWh/day)
  - This Year 3.346 MWh (17.270 kWh/day) 3.646 MWh (18.821 kWh/day) 0.300 MWh (1.551 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.797 MWh (17.503 kW/day) 35.598 MWh (18.999 kW/day) 2.802 MWh (1.495 kW/day)
Lifetime Since Install 32.831 MWh 36.178 MWh 3.348 MWh
Voltage/Current 248.8 V / 9.6 A 248.7 V / 3.3 A 248.8 V / -6.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/08/2020 21:45 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.502 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.197 0.369 0.776 4.018 0.000 kW
0.371 kWh
0.000 kW
2.223 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.364 0.748 3.902
03 - 202224****** IQ7+M [5] VCOP 0.000 0.197 0.377 0.727 3.849
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.373 0.690 3.652
05 - 202244****** IQ7+M [5] VCOP 0.000 0.198 0.376 0.796 4.177
06 - 202245****** IQ7+M [5] VCOP 0.000 0.197 0.364 0.794 4.167
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 0.434 0.999 4.930 0.000 kW
0.449 kWh
0.000 kW
2.244 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 0.433 0.940 4.434
09 - 202217****** IQ7+ [5] VCOP 0.000 0.275 0.462 1.050 5.255
10 - 202244****** IQ7+M [5] VCOP 0.000 0.277 0.462 1.050 5.230
11 - 202224****** IQ7+M [5] VCOP 0.000 0.272 0.454 1.014 4.903
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.072 0.256 0.347 2.078 0.000 kW
0.259 kWh
0.000 kW
1.034 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.072 0.259 0.387 2.276
14 - 202216****** IQ7+ [5] VCOP 0.000 0.073 0.262 0.386 2.271
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.257 0.377 2.217
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.70 V Current/Power 164.31 A (8.659 kW)
Remain Capacity/Energy 371.7 Ah (19.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Run Time 1h 20m to full Report Date 2020-12-08 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.70 V Cell (MIN/MAX) 3.284 V / 3.307 V (0.023 V)
Current/Power -0.57 A (-30 W) Runtime 9d 0h 36m to empty
Remain Capacity/Energy 123.9 Ah (6.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-08 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.285 V 3.284 V 3.285 V 3.285 V 3.291 V 3.286 V 3.289 V 3.287 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.298 V 3.289 V 3.303 V 3.291 V 3.303 V 3.305 V 3.305 V 3.307 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -