Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.345 kW
07/13/2025 17:47 (1873 days) Production Consumption NET Usage
Now 2.198 kW 0.853 kW -1.345 kW
Today 19.250 kWh (1.080 kW) 22.342 kWh (1.254 kW) 3.092 kWh (0.173 kW)
  - This Week 19.250 kWh (25.924 kWh/day) 22.342 kWh (30.087 kWh/day) 3.092 kWh (4.164 kWh/day)
  - This Month 316.328 kWh (24.825 kWh/day) 519.200 kWh (40.746 kWh/day) 202.872 kWh (15.921 kWh/day)
  - This Year 3.346 MWh (17.271 kWh/day) 3.646 MWh (18.821 kWh/day) 0.300 MWh (1.551 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.797 MWh (17.503 kW/day) 35.598 MWh (18.999 kW/day) 2.801 MWh (1.495 kW/day)
Lifetime Since Install 32.831 MWh 36.178 MWh 3.348 MWh
Voltage/Current 248.7 V / 8.8 A 248.8 V / 3.4 A 248.7 V / -5.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/19/2020 21:32 (8.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.002 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.000 1.973 0.000 kW
0.005 kWh
0.000 kW
0.028 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.001 0.000 0.000 1.906
03 - 202224****** IQ7+M [5] VCOP 0.000 0.003 0.004 0.000 1.897
04 - 202232****** IQ7+ [5] VCOP 0.000 0.003 0.004 0.000 1.820
05 - 202244****** IQ7+M [5] VCOP 0.000 0.004 0.008 0.001 1.998
06 - 202245****** IQ7+M [5] VCOP 0.000 0.005 0.012 0.004 2.040
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.003 0.004 0.000 2.313 0.000 kW
0.028 kWh
0.000 kW
0.139 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.003 0.005 0.000 0.044
09 - 202217****** IQ7+ [5] VCOP 0.000 0.009 0.033 0.012 2.470
10 - 202244****** IQ7+M [5] VCOP 0.000 0.025 0.081 0.018 2.458
11 - 202224****** IQ7+M [5] VCOP 0.000 0.007 0.016 0.008 2.293
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.057 0.233 0.111 1.278 0.000 kW
0.209 kWh
0.000 kW
0.835 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.022 0.090 0.074 1.314
14 - 202216****** IQ7+ [5] VCOP 0.000 0.018 0.078 0.063 1.304
15 - 202245****** IQ7+M [5] VCOP 0.000 0.111 0.435 0.365 1.669
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.41 V Current/Power 163.65 A (8.576 kW)
Remain Capacity/Energy 292.5 Ah (15.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 49.5 % State Of Health 98.5 %
Run Time 1h 49m to full Report Date 2020-12-19 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.41 V Cell (MIN/MAX) 3.270 V / 3.280 V (0.010 V)
Current/Power -0.52 A (-27 W) Runtime 7d 20h 35m to empty
Remain Capacity/Energy 97.5 Ah (5.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 49.5 % State Of Health 98.5 %
Temperature 20.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-19 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.270 V 3.270 V 3.272 V 3.272 V 3.273 V 3.273 V 3.274 V 3.274 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.276 V 3.276 V 3.277 V 3.277 V 3.278 V 3.278 V 3.279 V 3.280 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -