Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.414 kW
07/13/2025 15:10 (1873 days) Production Consumption NET Usage
Now 4.129 kW 2.715 kW -1.414 kW
Today 12.745 kWh (0.839 kW) 15.684 kWh (1.032 kW) 2.939 kWh (0.193 kW)
  - This Week 12.745 kWh (20.127 kWh/day) 15.684 kWh (24.768 kWh/day) 2.939 kWh (4.641 kWh/day)
  - This Month 309.823 kWh (24.525 kWh/day) 512.542 kWh (40.571 kWh/day) 202.719 kWh (16.047 kWh/day)
  - This Year 3.340 MWh (17.247 kWh/day) 3.640 MWh (18.797 kWh/day) 0.300 MWh (1.551 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.790 MWh (17.501 kW/day) 35.592 MWh (18.996 kW/day) 2.801 MWh (1.495 kW/day)
Lifetime Since Install 32.824 MWh 36.172 MWh 3.347 MWh
Voltage/Current 248.5 V / 16.6 A 248.4 V / 10.9 A 248.5 V / -5.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/20/2020 21:29 (7.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 0.420 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.000 1.866 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 1.801
03 - 202224****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.004 1.792
04 - 202232****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.004 1.720
05 - 202244****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.008 1.903
06 - 202245****** IQ7+M [5] VCOP 0.000 0.002 0.000 0.012 1.946
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.000 0.000 0.004 2.223 0.000 kW
0.017 kWh
0.000 kW
0.083 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.005 0.049
09 - 202217****** IQ7+ [5] VCOP 0.000 0.013 0.022 0.033 2.407
10 - 202244****** IQ7+M [5] VCOP 0.000 0.038 0.062 0.081 2.442
11 - 202224****** IQ7+M [5] VCOP 0.000 0.003 0.000 0.016 2.215
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.047 0.093 0.233 1.404 0.000 kW
0.084 kWh
0.000 kW
0.337 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.028 0.053 0.090 1.296
14 - 202216****** IQ7+ [5] VCOP 0.000 0.025 0.051 0.078 1.272
15 - 202245****** IQ7+M [5] VCOP 0.000 0.049 0.138 0.435 1.996
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.39 V Current/Power 163.59 A (8.570 kW)
Remain Capacity/Energy 256.2 Ah (13.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 43.4 % State Of Health 98.5 %
Run Time 2h 2m to full Report Date 2020-12-20 23:31
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.39 V Cell (MIN/MAX) 3.269 V / 3.279 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 7d 2h 8m to empty
Remain Capacity/Energy 85.4 Ah (4.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 43.4 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-20 23:31
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.269 V 3.269 V 3.271 V 3.270 V 3.273 V 3.272 V 3.272 V 3.274 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.275 V 3.274 V 3.276 V 3.275 V 3.277 V 3.277 V 3.278 V 3.279 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -