Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.796 kW
04/06/2026 21:23 (2140 days) Production Consumption NET Usage
Now 0.316 kW -1.480 kW -1.796 kW
Today 30.629 kWh (1.431 kW) 8.876 kWh (0.415 kW) -21.753 kWh (-1.017 kW)
  - This Week 35.090 kWh (18.555 kWh/day) 28.481 kWh (15.060 kWh/day) -6.609 kWh (-3.495 kWh/day)
  - This Month 87.695 kWh (14.886 kWh/day) 89.540 kWh (15.199 kWh/day) 1.845 kWh (0.313 kWh/day)
  - This Year 1.317 MWh (13.735 kWh/day) 1.655 MWh (17.258 kWh/day) 0.338 MWh (3.522 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 105.777 kWh (15.111 kWh/day) 106.523 kWh (15.218 kWh/day) 0.746 kWh (0.107 kWh/day)
Last 30 Days (03/07/2026) 589.484 kWh (19.649 kWh/day) 450.410 kWh (15.014 kWh/day) -139.074 kWh (-4.636 kWh/day)
Last One Year 6.127 MWh (16.785 kWh/day) 7.837 MWh (21.470 kWh/day) 1.710 MWh (4.685 kWh/day)
Lifetime Since PTO 36.883 MWh (17.228 kW/day) 41.166 MWh (19.228 kW/day) 4.283 MWh (2.001 kW/day)
Lifetime Since Install 36.917 MWh 41.746 MWh 4.829 MWh
Voltage/Current 249.2 V / 1.3 A 249.3 V / -5.9 A 249.2 V / -7.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/19/2021 23:09 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.361 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.269 1.856 1.473 8.555 0.000 kW
1.826 kWh
0.000 kW
10.957 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.265 1.825 1.409 8.284
03 - 202224****** IQ7+M [0] ---- 0.000 0.271 1.873 1.480 8.560
04 - 202232****** IQ7+ [0] ---- 0.000 0.272 1.852 1.458 8.478
05 - 202244****** IQ7+M [0] ---- 0.000 0.269 1.785 1.420 8.228
06 - 202245****** IQ7+M [0] ---- 0.000 0.264 1.766 1.403 8.183
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 1.965 1.526 8.611 0.000 kW
1.935 kWh
0.000 kW
9.676 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.838 1.408 8.169
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.950 1.521 8.639
10 - 202244****** IQ7+M [0] ---- 0.000 0.290 1.955 1.529 8.668
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.968 1.530 8.656
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.208 1.446 1.167 7.163 0.000 kW
1.432 kWh
0.000 kW
5.728 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.207 1.396 1.136 7.073
14 - 202216****** IQ7+ [0] ---- 0.000 0.208 1.457 1.176 7.228
15 - 202245****** IQ7+M [0] ---- 0.000 0.205 1.429 1.153 7.096
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.22 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 511.2 Ah (26.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.2 % State Of Health 100.0 %
Run Time 17d 17h 59m to empty Report Date 2021-09-19 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.