Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.067 kW
12/22/2025 10:53 (2035 days) Production Consumption NET Usage
Now 2.366 kW 0.299 kW -2.067 kW
Today 3.307 kWh (0.304 kW) 6.301 kWh (0.579 kW) 2.994 kWh (0.275 kW)
  - This Week 12.904 kWh (8.875 kWh/day) 23.035 kWh (15.843 kWh/day) 10.131 kWh (6.968 kWh/day)
  - This Month 187.810 kWh (8.754 kWh/day) 446.316 kWh (20.803 kWh/day) 258.506 kWh (12.049 kWh/day)
  - This Year 6.057 MWh (17.040 kWh/day) 7.363 MWh (20.713 kWh/day) 1.306 MWh (3.674 kWh/day)
Yesterday 9.597 kWh (0.400 kW) 16.734 kWh (0.697 kW) 7.137 kWh (0.297 kW)
Last 7 Days 63.452 kWh (9.064 kWh/day) 161.752 kWh (23.106 kWh/day) 98.300 kWh (14.042 kWh/day)
Last 30 Days 259.643 kWh (8.655 kWh/day) 622.166 kWh (20.739 kWh/day) 362.523 kWh (12.084 kWh/day)
Last One Year 6.123 MWh (16.774 kWh/day) 7.596 MWh (20.811 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 35.508 MWh (17.444 kW/day) 39.315 MWh (19.315 kW/day) 3.808 MWh (1.871 kW/day)
Lifetime Since Install 35.542 MWh 39.895 MWh 4.354 MWh
Voltage/Current 250.8 V / 9.4 A 250.7 V / 1.2 A 250.8 V / -8.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/23/2021 23:39 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.600 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.295 0.449 12.799 0.000 kW
2.171 kWh
0.000 kW
13.028 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 2.186 0.416 12.226
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.174 0.440 12.271
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.197 0.435 12.382
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.956 0.407 11.179
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.220 0.424 12.378
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.914 0.392 11.126 0.000 kW
2.002 kWh
0.000 kW
10.012 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.027 0.389 11.381
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.977 0.397 11.296
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.046 0.401 11.519
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.049 0.396 11.559
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.286 2.434 0.536 13.024 0.000 kW
2.390 kWh
0.000 kW
9.560 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.284 2.334 0.538 12.648
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 2.423 0.546 13.020
15 - 202245****** IQ7+M [5] VCOP 0.000 0.281 2.370 0.532 12.804
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 524.7 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 24d 7h 0m to empty Report Date 2021-06-23 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.