Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.228 kW
12/22/2025 14:48 (2035 days) Production Consumption NET Usage
Now 0.845 kW 0.617 kW -0.228 kW
Today 12.345 kWh (0.834 kW) 8.500 kWh (0.574 kW) -3.845 kWh (-0.260 kW)
  - This Week 21.942 kWh (13.568 kWh/day) 25.234 kWh (15.604 kWh/day) 3.292 kWh (2.036 kWh/day)
  - This Month 196.848 kWh (9.106 kWh/day) 448.515 kWh (20.748 kWh/day) 251.667 kWh (11.642 kWh/day)
  - This Year 6.066 MWh (17.057 kWh/day) 7.365 MWh (20.710 kWh/day) 1.299 MWh (3.653 kWh/day)
Yesterday 9.597 kWh (0.400 kW) 16.734 kWh (0.697 kW) 7.137 kWh (0.297 kW)
Last 7 Days 63.452 kWh (9.064 kWh/day) 161.752 kWh (23.106 kWh/day) 98.300 kWh (14.042 kWh/day)
Last 30 Days 259.643 kWh (8.655 kWh/day) 622.166 kWh (20.739 kWh/day) 362.523 kWh (12.084 kWh/day)
Last One Year 6.123 MWh (16.774 kWh/day) 7.596 MWh (20.811 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 35.517 MWh (17.447 kW/day) 39.318 MWh (19.314 kW/day) 3.801 MWh (1.867 kW/day)
Lifetime Since Install 35.551 MWh 39.898 MWh 4.347 MWh
Voltage/Current 250.0 V / 3.4 A 250.0 V / 2.5 A 250.0 V / -0.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/26/2021 23:27 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.505 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.288 2.021 1.108 10.597 0.000 kW
1.970 kWh
0.000 kW
11.817 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.958 1.082 10.191
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.995 1.111 10.378
04 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.994 1.105 10.426
05 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.893 1.074 9.642
06 - 202245****** IQ7+M [5] VCOP 0.000 0.280 1.957 1.082 10.235
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.281 1.888 1.035 9.506 0.000 kW
1.922 kWh
0.000 kW
9.612 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.281 1.925 1.059 9.694
09 - 202217****** IQ7+ [5] VCOP 0.000 0.281 1.907 1.057 9.643
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.943 1.077 9.841
11 - 202224****** IQ7+M [5] VCOP 0.000 0.282 1.949 1.072 9.840
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.246 1.795 0.999 10.450 0.000 kW
1.769 kWh
0.000 kW
7.076 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.245 1.718 0.983 10.231
14 - 202216****** IQ7+ [5] VCOP 0.000 0.247 1.795 1.013 10.483
15 - 202245****** IQ7+M [5] VCOP 0.000 0.242 1.767 1.003 10.348
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 531.3 Ah (27.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.5 % State Of Health 100.0 %
Run Time 24d 14h 20m to empty Report Date 2021-07-26 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.