Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.064 kW
04/08/2026 04:47 (2142 days) Production Consumption NET Usage
Now 0.317 kW 0.381 kW 0.064 kW
Today 1.521 kWh (0.317 kW) 2.556 kWh (0.533 kW) 1.035 kWh (0.216 kW)
  - This Week 73.044 kWh (22.828 kWh/day) 38.118 kWh (11.913 kWh/day) -34.926 kWh (-10.915 kWh/day)
  - This Month 125.649 kWh (17.452 kWh/day) 99.177 kWh (13.775 kWh/day) -26.472 kWh (-3.677 kWh/day)
  - This Year 1.355 MWh (13.941 kWh/day) 1.665 MWh (17.125 kWh/day) 0.309 MWh (3.184 kWh/day)
Yesterday 35.605 kWh (1.484 kW) 10.861 kWh (0.453 kW) -24.744 kWh (-1.031 kW)
Last 7 Days 125.649 kWh (17.950 kWh/day) 97.145 kWh (13.878 kWh/day) -28.504 kWh (-4.072 kWh/day)
Last 30 Days (03/09/2026) 616.712 kWh (20.557 kWh/day) 443.692 kWh (14.790 kWh/day) -173.020 kWh (-5.767 kWh/day)
Last One Year 6.162 MWh (16.882 kWh/day) 7.827 MWh (21.445 kWh/day) 1.666 MWh (4.563 kWh/day)
Lifetime Since PTO 36.921 MWh (17.235 kW/day) 41.175 MWh (19.221 kW/day) 4.255 MWh (1.986 kW/day)
Lifetime Since Install 36.955 MWh 41.755 MWh 4.801 MWh
Voltage/Current 251.2 V / 1.3 A 251.2 V / 1.5 A 251.2 V / 0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/13/2021 21:45 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.392 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.208 0.610 0.274 6.449 0.000 kW
0.598 kWh
0.000 kW
3.590 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.208 0.580 0.251 6.025
03 - 202224****** IQ7+M [0] ---- 0.000 0.216 0.615 0.291 6.427
04 - 202232****** IQ7+ [0] ---- 0.000 0.213 0.595 0.280 6.190
05 - 202244****** IQ7+M [0] ---- 0.000 0.210 0.596 0.281 6.360
06 - 202245****** IQ7+M [0] ---- 0.000 0.199 0.594 0.265 6.166
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.228 0.579 0.344 7.277 0.000 kW
0.594 kWh
0.000 kW
2.970 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.234 0.475 0.345 6.402
09 - 202217****** IQ7+ [0] ---- 0.000 0.245 0.670 0.386 8.084
10 - 202244****** IQ7+M [0] ---- 0.000 0.231 0.657 0.372 7.891
11 - 202224****** IQ7+M [0] ---- 0.000 0.232 0.589 0.368 7.531
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.145 0.454 0.184 3.527 0.000 kW
0.458 kWh
0.000 kW
1.832 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.143 0.462 0.193 3.803
14 - 202216****** IQ7+ [0] ---- 0.000 0.146 0.461 0.197 3.813
15 - 202245****** IQ7+M [0] ---- 0.000 0.143 0.454 0.195 3.754
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.53 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 198.9 Ah (10.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 33.1 % State Of Health 100.0 %
Run Time 4d 14h 30m to empty Report Date 2021-11-13 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.53 V Cell (MIN/MAX) 3.276 V / 3.287 V (0.011 V)
Current/Power -0.50 A (-26 W) Runtime 5d 12h 36m to empty
Remain Capacity/Energy 66.3 Ah (3.4 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 33.1 % State Of Health 100.0 %
Temperature 23.0 °C Cycle 49
MOSFET CFET = ON, DFET = ON Reported 2021-11-13 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.276 V 3.280 V 3.279 V 3.281 V 3.281 V 3.282 V 3.282 V 3.282 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.284 V 3.284 V 3.285 V 3.286 V 3.286 V 3.287 V 3.287 V 3.287 V
pack voltage and current cell voltages
pack temperature
Voltage 52.54 V Cell (MIN/MAX) 3.283 V / 3.284 V (0.001 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 48.9 Ah (2.5 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 48.9 % State Of Health 100.0 %
Temperature 25.9 °C Cycle 8
MOSFET CFET = ON, DFET = ON Reported 2021-11-13 23:55
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.283 V 3.283 V 3.284 V 3.283 V 3.284 V 3.284 V 3.283 V 3.284 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.283 V 3.283 V 3.284 V 3.284 V 3.283 V 3.284 V 3.284 V 3.283 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_2.png". Check that the process running PHP has enough permission.