Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.312 kW
12/22/2025 16:15 (2035 days) Production Consumption NET Usage
Now 0.034 kW 0.346 kW 0.312 kW
Today 12.900 kWh (0.793 kW) 9.444 kWh (0.581 kW) -3.456 kWh (-0.212 kW)
  - This Week 22.497 kWh (13.406 kWh/day) 26.178 kWh (15.599 kWh/day) 3.681 kWh (2.193 kWh/day)
  - This Month 197.403 kWh (9.106 kWh/day) 449.459 kWh (20.733 kWh/day) 252.056 kWh (11.627 kWh/day)
  - This Year 6.066 MWh (17.056 kWh/day) 7.366 MWh (20.709 kWh/day) 1.299 MWh (3.653 kWh/day)
Yesterday 9.597 kWh (0.400 kW) 16.734 kWh (0.697 kW) 7.137 kWh (0.297 kW)
Last 7 Days 63.452 kWh (9.064 kWh/day) 161.752 kWh (23.106 kWh/day) 98.300 kWh (14.042 kWh/day)
Last 30 Days 259.643 kWh (8.655 kWh/day) 622.166 kWh (20.739 kWh/day) 362.523 kWh (12.084 kWh/day)
Last One Year 6.123 MWh (16.774 kWh/day) 7.596 MWh (20.811 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 35.517 MWh (17.447 kW/day) 39.319 MWh (19.314 kW/day) 3.801 MWh (1.867 kW/day)
Lifetime Since Install 35.551 MWh 39.898 MWh 4.347 MWh
Voltage/Current 247.9 V / 0.1 A 247.9 V / 1.4 A 247.9 V / 1.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/06/2021 23:12 (13.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.391 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.841 1.606 11.389 0.000 kW
1.772 kWh
0.000 kW
10.630 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.758 1.566 10.960
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.812 1.601 11.169
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.831 1.600 11.261
05 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.639 1.556 10.452
06 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.749 1.575 11.002
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.697 1.492 10.325 0.000 kW
1.718 kWh
0.000 kW
8.589 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.708 1.563 10.542
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.713 1.525 10.436
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.732 1.581 10.683
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.738 1.582 10.711
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.265 1.811 1.405 11.048 0.000 kW
1.793 kWh
0.000 kW
7.172 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.263 1.756 1.352 10.721
14 - 202216****** IQ7+ [5] VCOP 0.000 0.266 1.819 1.416 11.069
15 - 202245****** IQ7+M [5] VCOP 0.000 0.260 1.786 1.388 10.899
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 523.8 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.3 % State Of Health 100.0 %
Run Time 18d 4h 29m to empty Report Date 2021-08-06 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.