Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.446 kW
04/06/2026 16:38 (2140 days) Production Consumption NET Usage
Now 1.610 kW 0.164 kW -1.446 kW
Today 27.326 kWh (1.641 kW) 1.954 kWh (0.117 kW) -25.372 kWh (-1.523 kW)
  - This Week 31.787 kWh (18.771 kWh/day) 21.559 kWh (12.731 kWh/day) -10.228 kWh (-6.040 kWh/day)
  - This Month 84.392 kWh (14.822 kWh/day) 82.618 kWh (14.511 kWh/day) -1.774 kWh (-0.312 kWh/day)
  - This Year 1.314 MWh (13.729 kWh/day) 1.648 MWh (17.221 kWh/day) 0.334 MWh (3.492 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 104.916 kWh (14.988 kWh/day) 99.299 kWh (14.186 kWh/day) -5.617 kWh (-0.802 kWh/day)
Last 30 Days (03/07/2026) 586.761 kWh (19.559 kWh/day) 447.869 kWh (14.929 kWh/day) -138.892 kWh (-4.630 kWh/day)
Last One Year 6.124 MWh (16.779 kWh/day) 7.834 MWh (21.464 kWh/day) 1.710 MWh (4.685 kWh/day)
Lifetime Since PTO 36.879 MWh (17.228 kW/day) 41.159 MWh (19.227 kW/day) 4.279 MWh (1.999 kW/day)
Lifetime Since Install 36.913 MWh 41.739 MWh 4.825 MWh
Voltage/Current 249.4 V / 6.5 A 249.3 V / 0.7 A 249.4 V / -5.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/29/2021 22:17 (9.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.106 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.577 0.157 4.252 0.000 kW
0.571 kWh
0.000 kW
3.428 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.214 0.545 0.139 4.005
03 - 202224****** IQ7+M [5] VCOP 0.000 0.220 0.596 0.157 4.260
04 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.579 0.150 4.127
05 - 202244****** IQ7+M [5] VCOP 0.000 0.219 0.580 0.143 4.121
06 - 202245****** IQ7+M [5] VCOP 0.000 0.218 0.551 0.148 4.079
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.262 0.632 0.144 4.719 0.000 kW
0.629 kWh
0.000 kW
3.143 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.260 0.533 0.143 4.243
09 - 202217****** IQ7+ [5] VCOP 0.000 0.261 0.682 0.145 4.989
10 - 202244****** IQ7+M [5] VCOP 0.000 0.262 0.659 0.145 4.865
11 - 202224****** IQ7+M [5] VCOP 0.000 0.262 0.637 0.145 4.704
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.129 0.373 0.152 2.381 0.000 kW
0.384 kWh
0.000 kW
1.534 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.385 0.153 2.513
14 - 202216****** IQ7+ [5] VCOP 0.000 0.129 0.392 0.156 2.540
15 - 202245****** IQ7+M [5] VCOP 0.000 0.127 0.384 0.154 2.492
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.63 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 320.1 Ah (16.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.4 % State Of Health 100.0 %
Run Time 11d 2h 44m to empty Report Date 2021-11-29 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.