Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.566 kW
07/14/2025 14:04 (1874 days) Production Consumption NET Usage
Now 4.253 kW 2.687 kW -1.566 kW
Today 11.732 kWh (0.831 kW) 11.757 kWh (0.833 kW) 0.025 kWh (0.002 kW)
  - This Week 32.579 kWh (20.522 kWh/day) 45.680 kWh (28.775 kWh/day) 13.101 kWh (8.253 kWh/day)
  - This Month 329.657 kWh (24.262 kWh/day) 542.538 kWh (39.930 kWh/day) 212.881 kWh (15.668 kWh/day)
  - This Year 3.359 MWh (17.264 kWh/day) 3.670 MWh (18.859 kWh/day) 0.310 MWh (1.595 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.810 MWh (17.503 kW/day) 35.622 MWh (19.002 kW/day) 2.811 MWh (1.500 kW/day)
Lifetime Since Install 32.844 MWh 36.202 MWh 3.358 MWh
Voltage/Current 249.2 V / 17.1 A 249.1 V / 10.8 A 249.2 V / -6.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/27/2021 23:55 (13.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.895 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.282 1.326 2.406 12.541 0.000 kW
1.308 kWh
0.000 kW
7.850 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 1.294 2.340 12.182
03 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.328 2.383 12.474
04 - 202232****** IQ7+ [5] VCOP 0.000 0.283 1.326 2.412 12.621
05 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.290 2.216 11.535
06 - 202245****** IQ7+M [5] VCOP 0.000 0.278 1.286 2.314 12.010
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.277 2.245 11.736 0.000 kW
1.298 kWh
0.000 kW
6.489 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.295 2.306 11.794
09 - 202217****** IQ7+ [5] VCOP 0.000 0.284 1.287 2.252 11.797
10 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.320 2.332 12.119
11 - 202224****** IQ7+M [5] VCOP 0.000 0.284 1.310 2.356 12.152
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.224 1.143 2.236 12.041 0.000 kW
1.139 kWh
0.000 kW
4.556 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.221 1.119 2.105 11.621
14 - 202216****** IQ7+ [5] VCOP 0.000 0.225 1.155 2.225 12.021
15 - 202245****** IQ7+M [5] VCOP 0.000 0.225 1.138 2.188 11.832
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.06 V Current/Power -12.15 A (-0.645 kW)
Remain Capacity/Energy 445.2 Ah (22.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 74.2 % State Of Health 100.0 %
Run Time 1d 12h 38m to empty Report Date 2021-04-27 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.