Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.362 kW
05/22/2026 17:51 (2186 days) Production Consumption NET Usage
Now 0.508 kW 0.146 kW -0.362 kW
Today 29.041 kWh (1.624 kW) 2.393 kWh (0.134 kW) -26.648 kWh (-1.491 kW)
  - This Week 154.818 kWh (26.948 kWh/day) 146.557 kWh (25.510 kWh/day) -8.261 kWh (-1.438 kWh/day)
  - This Month 556.634 kWh (25.599 kWh/day) 346.279 kWh (15.925 kWh/day) -210.355 kWh (-9.674 kWh/day)
  - This Year 2.510 MWh (17.706 kWh/day) 2.406 MWh (16.974 kWh/day) -0.104 MWh (-0.731 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.571 kWh (26.939 kWh/day) 156.941 kWh (22.420 kWh/day) -31.630 kWh (-4.519 kWh/day)
Last 30 Days (04/22/2026) 720.793 kWh (24.026 kWh/day) 419.869 kWh (13.996 kWh/day) -300.924 kWh (-10.031 kWh/day)
Last One Year 6.391 MWh (17.510 kWh/day) 7.791 MWh (21.346 kWh/day) 1.400 MWh (3.836 kWh/day)
Lifetime Since PTO 38.075 MWh (17.412 kW/day) 41.917 MWh (19.169 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.109 MWh 42.497 MWh 4.387 MWh
Voltage/Current 249.3 V / 2.0 A 249.4 V / 0.6 A 249.3 V / -1.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/13/2022 23:52 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.904 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.129 0.049 5.717 0.000 kW
1.040 kWh
0.000 kW
6.239 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.002 0.040 5.372
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.090 0.046 5.669
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.124 0.045 5.524
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 0.979 0.040 5.588
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 0.915 0.041 5.406
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 0.984 0.044 5.915 0.000 kW
1.137 kWh
0.000 kW
5.687 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 1.099 0.044 6.245
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.213 0.047 6.049
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.197 0.047 6.065
11 - 202224****** IQ7+M [5] VCOP 0.000 0.301 1.193 0.046 6.090
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.248 0.898 0.055 4.268 0.000 kW
0.994 kWh
0.000 kW
3.978 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.245 0.930 0.058 4.218
14 - 202216****** IQ7+ [5] VCOP 0.000 0.248 1.036 0.063 4.269
15 - 202245****** IQ7+M [5] VCOP 0.000 0.243 1.114 0.065 4.243
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.