Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.415 kW
12/22/2025 18:02 (2035 days) Production Consumption NET Usage
Now 0.000 kW 0.415 kW 0.415 kW
Today 12.903 kWh (0.715 kW) 10.728 kWh (0.594 kW) -2.175 kWh (-0.120 kW)
  - This Week 22.500 kWh (12.839 kWh/day) 27.462 kWh (15.670 kWh/day) 4.962 kWh (2.831 kWh/day)
  - This Month 197.406 kWh (9.075 kWh/day) 450.743 kWh (20.721 kWh/day) 253.337 kWh (11.646 kWh/day)
  - This Year 6.066 MWh (17.052 kWh/day) 7.367 MWh (20.708 kWh/day) 1.301 MWh (3.656 kWh/day)
Yesterday 9.597 kWh (0.400 kW) 16.734 kWh (0.697 kW) 7.137 kWh (0.297 kW)
Last 7 Days 63.452 kWh (9.064 kWh/day) 161.752 kWh (23.106 kWh/day) 98.300 kWh (14.042 kWh/day)
Last 30 Days 259.643 kWh (8.655 kWh/day) 622.166 kWh (20.739 kWh/day) 362.523 kWh (12.084 kWh/day)
Last One Year 6.123 MWh (16.774 kWh/day) 7.596 MWh (20.811 kWh/day) 1.474 MWh (4.037 kWh/day)
Lifetime Since PTO 35.517 MWh (17.446 kW/day) 39.320 MWh (19.314 kW/day) 3.803 MWh (1.868 kW/day)
Lifetime Since Install 35.551 MWh 39.900 MWh 4.349 MWh
Voltage/Current 248.9 V / 0.0 A 249.0 V / 1.7 A 249.0 V / 1.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/22/2021 21:10 (10.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.673 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.269 0.993 1.359 8.712 0.000 kW
0.956 kWh
0.000 kW
5.733 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.264 0.940 1.322 8.292
03 - 202224****** IQ7+M [0] ---- 0.000 0.266 0.971 1.351 8.641
04 - 202232****** IQ7+ [0] ---- 0.000 0.263 0.932 1.330 8.435
05 - 202244****** IQ7+M [0] ---- 0.000 0.266 0.961 1.336 8.519
06 - 202245****** IQ7+M [0] ---- 0.000 0.263 0.936 1.313 8.374
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 0.964 1.524 9.563 0.000 kW
0.963 kWh
0.000 kW
4.817 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.294 0.822 1.350 8.675
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.032 1.632 9.967
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.004 1.618 9.895
11 - 202224****** IQ7+M [0] ---- 0.000 0.294 0.996 1.578 9.819
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.174 0.778 0.806 5.628 0.000 kW
0.781 kWh
0.000 kW
3.122 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.173 0.779 0.838 5.748
14 - 202216****** IQ7+ [0] ---- 0.000 0.176 0.787 0.852 5.844
15 - 202245****** IQ7+M [0] ---- 0.000 0.173 0.777 0.838 5.748
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.20 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 519.9 Ah (26.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.7 % State Of Health 100.0 %
Run Time 14d 10h 36m to empty Report Date 2021-10-22 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.