Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.870 kW
05/22/2026 16:57 (2186 days) Production Consumption NET Usage
Now 1.164 kW 0.294 kW -0.870 kW
Today 28.201 kWh (1.662 kW) 1.171 kWh (0.069 kW) -27.030 kWh (-1.593 kW)
  - This Week 153.978 kWh (26.979 kWh/day) 145.335 kWh (25.465 kWh/day) -8.643 kWh (-1.514 kWh/day)
  - This Month 555.794 kWh (25.605 kWh/day) 345.057 kWh (15.896 kWh/day) -210.737 kWh (-9.708 kWh/day)
  - This Year 2.509 MWh (17.704 kWh/day) 2.405 MWh (16.970 kWh/day) -0.104 MWh (-0.734 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 189.044 kWh (27.006 kWh/day) 156.192 kWh (22.313 kWh/day) -32.852 kWh (-4.693 kWh/day)
Last 30 Days (04/22/2026) 720.392 kWh (24.013 kWh/day) 418.907 kWh (13.964 kWh/day) -301.485 kWh (-10.050 kWh/day)
Last One Year 6.391 MWh (17.509 kWh/day) 7.790 MWh (21.343 kWh/day) 1.400 MWh (3.834 kWh/day)
Lifetime Since PTO 38.075 MWh (17.412 kW/day) 41.916 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.108 MWh 42.496 MWh 4.387 MWh
Voltage/Current 247.3 V / 4.7 A 247.2 V / 1.2 A 247.2 V / -3.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/28/2022 22:30 (13.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 34.025 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.455 1.847 10.615 0.000 kW
2.355 kWh
0.000 kW
14.130 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.317 1.730 10.007
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.403 1.823 10.573
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.381 1.797 10.390
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.263 1.649 9.826
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.311 1.704 9.975
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 2.335 1.708 9.956 0.000 kW
2.312 kWh
0.000 kW
11.559 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.278 1.712 10.033
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 2.234 1.709 9.966
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.322 1.750 10.099
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.390 1.755 10.212
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.280 2.126 1.841 9.978 0.000 kW
2.084 kWh
0.000 kW
8.337 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.277 1.992 1.754 9.626
14 - 202216****** IQ7+ [5] VCOP 0.000 0.280 2.131 1.850 10.092
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 2.088 1.824 9.951
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.07 V Current/Power -11.75 A (-0.624 kW)
Remain Capacity/Energy 498.9 Ah (25.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.2 % State Of Health 100.0 %
Run Time 1d 18h 27m to empty Report Date 2022-04-28 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.05 V Cell (MIN/MAX) 3.310 V / 3.320 V (0.010 V)
Current/Power -3.28 A (-174 W) Runtime 2d 2h 38m to empty
Remain Capacity/Energy 166.3 Ah (8.5 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 83.2 % State Of Health 100.0 %
Temperature 20.0 °C Cycle 63
MOSFET CFET = ON, DFET = ON Reported 2022-04-28 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.310 V 3.310 V 3.312 V 3.313 V 3.314 V 3.312 V 3.313 V 3.316 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.318 V 3.316 V 3.317 V 3.317 V 3.320 V 3.319 V 3.320 V 3.320 V
pack voltage and current cell voltages
pack temperature
Voltage 53.07 V Cell (MIN/MAX) 3.315 V / 3.317 V (0.002 V)
Current/Power -1.90 A (-100 W) Runtime 2d 1h 42m to empty
Remain Capacity/Energy 94.5 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 94.5 % State Of Health 100.0 %
Temperature 20.4 °C Cycle 16
MOSFET CFET = ON, DFET = ON Reported 2022-04-28 23:54
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.315 V 3.316 V 3.317 V 3.316 V 3.317 V 3.317 V 3.315 V 3.317 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.317 V 3.316 V 3.316 V 3.316 V 3.317 V 3.317 V 3.317 V 3.315 V
pack voltage and current cell voltages
pack temperature
Voltage 53.10 V Cell (MIN/MAX) 3.318 V / 3.319 V (0.001 V)
Current/Power -2.04 A (-108 W) Runtime 1d 21h 51m to empty
Remain Capacity/Energy 93.7 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.7 % State Of Health 100.0 %
Temperature 21.6 °C Cycle 16
MOSFET CFET = ON, DFET = ON Reported 2022-04-28 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.319 V 3.319 V 3.318 V 3.319 V 3.319 V 3.319 V 3.319 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.319 V 3.318 V 3.319 V 3.319 V 3.318 V 3.318 V 3.319 V 3.318 V
pack voltage and current cell voltages
pack temperature
Voltage 53.07 V Cell (MIN/MAX) 3.316 V / 3.318 V (0.002 V)
Current/Power -2.13 A (-112 W) Runtime 1d 19h 56m to empty
Remain Capacity/Energy 93.5 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.5 % State Of Health 100.0 %
Temperature 22.3 °C Cycle 16
MOSFET CFET = ON, DFET = ON Reported 2022-04-28 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.317 V 3.317 V 3.318 V 3.317 V 3.316 V 3.317 V 3.317 V 3.317 V
pack voltage and current cell voltages
pack temperature
Voltage 53.07 V Cell (MIN/MAX) 3.316 V / 3.318 V (0.002 V)
Current/Power -2.03 A (-107 W) Runtime 1d 22h 10m to empty
Remain Capacity/Energy 93.7 Ah (4.8 kWh) Full Capacity/Energy 99.7 Ah (5.1 kWh)
State Of Charge 94.0 % State Of Health 99.7 %
Temperature 21.1 °C Cycle 16
MOSFET CFET = ON, DFET = ON Reported 2022-04-28 23:53
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.316 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.317 V 3.318 V 3.317 V 3.316 V 3.317 V 3.317 V 3.317 V 3.317 V
pack voltage and current cell voltages
pack temperature