Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.459 kW
05/22/2026 16:07 (2186 days) Production Consumption NET Usage
Now 2.260 kW -0.199 kW -2.459 kW
Today 26.931 kWh (1.669 kW) 0.331 kWh (0.021 kW) -26.600 kWh (-1.648 kW)
  - This Week 152.708 kWh (26.920 kWh/day) 144.495 kWh (25.472 kWh/day) -8.213 kWh (-1.448 kWh/day)
  - This Month 554.524 kWh (25.587 kWh/day) 344.217 kWh (15.883 kWh/day) -210.307 kWh (-9.704 kWh/day)
  - This Year 2.508 MWh (17.700 kWh/day) 2.404 MWh (16.968 kWh/day) -0.104 MWh (-0.731 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.438 kWh (26.920 kWh/day) 155.831 kWh (22.262 kWh/day) -32.607 kWh (-4.658 kWh/day)
Last 30 Days (04/22/2026) 719.930 kWh (23.998 kWh/day) 418.536 kWh (13.951 kWh/day) -301.394 kWh (-10.046 kWh/day)
Last One Year 6.390 MWh (17.507 kWh/day) 7.790 MWh (21.343 kWh/day) 1.400 MWh (3.836 kWh/day)
Lifetime Since PTO 38.073 MWh (17.412 kW/day) 41.915 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.107 MWh 42.495 MWh 4.388 MWh
Voltage/Current 250.4 V / 9.0 A 250.3 V / -0.8 A 250.3 V / -9.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/11/2022 22:41 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.727 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.655 2.185 9.636 0.000 kW
1.582 kWh
0.000 kW
9.493 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.541 2.027 9.021
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.623 2.132 9.469
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.614 2.099 9.323
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.521 1.945 8.845
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.539 2.064 9.080
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.534 1.981 8.909 0.000 kW
1.534 kWh
0.000 kW
7.672 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.525 2.011 8.828
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.523 1.982 8.735
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.523 1.982 8.928
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.567 2.000 9.029
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.290 1.643 2.290 9.479 0.000 kW
1.640 kWh
0.000 kW
6.562 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.291 1.610 2.239 9.234
14 - 202216****** IQ7+ [5] VCOP 0.000 0.291 1.663 2.308 9.588
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.645 2.273 9.447
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.20 V Current/Power -2.31 A (-0.123 kW)
Remain Capacity/Energy 505.2 Ah (25.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.2 % State Of Health 100.0 %
Run Time 9d 2h 42m to empty Report Date 2022-05-11 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.