Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.714 kW
07/14/2025 19:47 (1874 days) Production Consumption NET Usage
Now 0.000 kW 0.714 kW 0.714 kW
Today 18.325 kWh (0.924 kW) 23.582 kWh (1.189 kW) 5.257 kWh (0.265 kW)
  - This Week 39.172 kWh (21.452 kWh/day) 57.505 kWh (31.492 kWh/day) 18.333 kWh (10.040 kWh/day)
  - This Month 336.250 kWh (24.320 kWh/day) 554.363 kWh (40.096 kWh/day) 218.113 kWh (15.776 kWh/day)
  - This Year 3.366 MWh (17.277 kWh/day) 3.682 MWh (18.897 kWh/day) 0.316 MWh (1.620 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.817 MWh (17.504 kW/day) 35.634 MWh (19.006 kW/day) 2.817 MWh (1.502 kW/day)
Lifetime Since Install 32.851 MWh 36.214 MWh 3.363 MWh
Voltage/Current 249.1 V / 0.0 A 249.1 V / 2.9 A 249.1 V / 2.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/08/2021 21:24 (13.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.485 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.287 0.942 2.021 10.153 0.000 kW
0.898 kWh
0.000 kW
5.386 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.286 0.906 1.925 9.722
03 - 202224****** IQ7+M [0] ---- 0.000 0.285 0.912 1.933 9.850
04 - 202232****** IQ7+ [0] ---- 0.000 0.287 0.924 1.958 9.894
05 - 202244****** IQ7+M [0] ---- 0.000 0.285 0.789 1.754 9.037
06 - 202245****** IQ7+M [0] ---- 0.000 0.281 0.913 1.944 9.812
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.281 0.788 1.768 8.972 0.000 kW
0.786 kWh
0.000 kW
3.932 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.280 0.775 1.802 9.058
09 - 202217****** IQ7+ [0] ---- 0.000 0.281 0.791 1.796 9.066
10 - 202244****** IQ7+M [0] ---- 0.000 0.280 0.792 1.827 9.180
11 - 202224****** IQ7+M [0] ---- 0.000 0.281 0.787 1.830 9.149
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.286 1.055 2.037 10.216 0.000 kW
1.042 kWh
0.000 kW
4.167 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.286 1.054 1.978 10.014
14 - 202216****** IQ7+ [0] ---- 0.000 0.287 1.001 2.036 10.286
15 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.057 2.009 10.144
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.11 V Current/Power -7.39 A (-0.392 kW)
Remain Capacity/Energy 495.3 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.6 % State Of Health 100.0 %
Run Time 2d 19h 1m to empty Report Date 2021-07-08 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.16 V Cell (MIN/MAX) 3.317 V / 3.327 V (0.010 V)
Current/Power -2.00 A (-106 W) Runtime 3d 10h 33m to empty
Remain Capacity/Energy 165.1 Ah (8.5 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 82.5 % State Of Health 100.0 %
Temperature 25.0 °C Cycle 41
MOSFET CFET = ON, DFET = ON Reported 2021-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.317 V 3.318 V 3.319 V 3.321 V 3.320 V 3.321 V 3.322 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.323 V 3.323 V 3.324 V 3.323 V 3.325 V 3.326 V 3.327 V 3.326 V
pack voltage and current cell voltages
pack temperature
Voltage 53.09 V Cell (MIN/MAX) 3.318 V / 3.319 V (0.001 V)
Current/Power -1.51 A (-80 W) Runtime 2d 13h 45m to empty
Remain Capacity/Energy 93.2 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.2 % State Of Health 100.0 %
Temperature 26.3 °C Cycle 5
MOSFET CFET = ON, DFET = ON Reported 2021-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.319 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.318 V 3.318 V
pack voltage and current cell voltages
pack temperature
Voltage 53.13 V Cell (MIN/MAX) 3.320 V / 3.321 V (0.001 V)
Current/Power -1.05 A (-55 W) Runtime 3d 17h 4m to empty
Remain Capacity/Energy 93.5 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.5 % State Of Health 100.0 %
Temperature 24.2 °C Cycle 5
MOSFET CFET = ON, DFET = ON Reported 2021-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.320 V 3.321 V 3.321 V 3.320 V 3.320 V 3.320 V 3.320 V 3.321 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.320 V 3.320 V 3.321 V 3.320 V 3.320 V 3.320 V 3.321 V 3.320 V
pack voltage and current cell voltages
pack temperature
Voltage 53.07 V Cell (MIN/MAX) 3.317 V / 3.318 V (0.001 V)
Current/Power -1.02 A (-54 W) Runtime 3d 19h 44m to empty
Remain Capacity/Energy 93.6 Ah (4.8 kWh) Full Capacity/Energy 100.0 Ah (5.1 kWh)
State Of Charge 93.6 % State Of Health 100.0 %
Temperature 24.0 °C Cycle 5
MOSFET CFET = ON, DFET = ON Reported 2021-07-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.317 V 3.318 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V 3.317 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_4.png". Check that the process running PHP has enough permission.