Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.689 kW
05/22/2026 17:06 (2186 days) Production Consumption NET Usage
Now 1.978 kW 0.289 kW -1.689 kW
Today 28.390 kWh (1.659 kW) 1.255 kWh (0.073 kW) -27.135 kWh (-1.585 kW)
  - This Week 154.167 kWh (26.984 kWh/day) 145.419 kWh (25.452 kWh/day) -8.748 kWh (-1.531 kWh/day)
  - This Month 555.983 kWh (25.606 kWh/day) 345.141 kWh (15.896 kWh/day) -210.842 kWh (-9.710 kWh/day)
  - This Year 2.509 MWh (17.705 kWh/day) 2.405 MWh (16.970 kWh/day) -0.104 MWh (-0.735 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 189.002 kWh (27.000 kWh/day) 156.239 kWh (22.320 kWh/day) -32.763 kWh (-4.680 kWh/day)
Last 30 Days (04/22/2026) 720.516 kWh (24.017 kWh/day) 418.972 kWh (13.966 kWh/day) -301.544 kWh (-10.051 kWh/day)
Last One Year 6.391 MWh (17.509 kWh/day) 7.790 MWh (21.344 kWh/day) 1.399 MWh (3.834 kWh/day)
Lifetime Since PTO 38.075 MWh (17.412 kW/day) 41.916 MWh (19.168 kW/day) 3.841 MWh (1.756 kW/day)
Lifetime Since Install 38.109 MWh 42.496 MWh 4.387 MWh
Voltage/Current 251.2 V / 7.9 A 251.1 V / 1.2 A 251.2 V / -6.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/31/2022 22:51 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.221 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 2.087 2.102 12.023 0.000 kW
1.972 kWh
0.000 kW
11.834 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.963 1.957 11.364
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.991 2.014 11.783
04 - 202232****** IQ7+ [5] VCOP 0.000 0.289 1.995 1.995 11.624
05 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.811 1.827 11.067
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.987 2.005 11.501
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.847 1.898 11.023 0.000 kW
1.840 kWh
0.000 kW
9.200 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.294 1.800 1.829 10.722
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.812 1.852 10.792
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.864 1.924 11.076
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.877 1.927 11.190
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.255 2.072 2.103 11.824 0.000 kW
2.047 kWh
0.000 kW
8.187 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.255 2.015 2.018 11.540
14 - 202216****** IQ7+ [5] VCOP 0.000 0.255 2.067 2.109 11.951
15 - 202245****** IQ7+M [5] VCOP 0.000 0.250 2.033 2.077 11.819
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.20 V Current/Power -1.26 A (-67 W)
Remain Capacity/Energy 525.0 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 17d 8h 40m to empty Report Date 2022-05-31 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.