Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.842 kW
04/06/2026 01:21 (2140 days) Production Consumption NET Usage
Now 0.000 kW 0.842 kW 0.842 kW
Today 0.000 kWh (0.000 kW) 1.080 kWh (0.788 kW) 1.080 kWh (0.788 kW)
  - This Week 4.461 kWh (4.222 kWh/day) 20.685 kWh (19.577 kWh/day) 16.224 kWh (15.355 kWh/day)
  - This Month 57.066 kWh (11.285 kWh/day) 81.744 kWh (16.166 kWh/day) 24.678 kWh (4.880 kWh/day)
  - This Year 1.286 MWh (13.534 kWh/day) 1.647 MWh (17.327 kWh/day) 0.361 MWh (3.794 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 101.302 kWh (14.472 kWh/day) 105.259 kWh (15.037 kWh/day) 3.957 kWh (0.565 kWh/day)
Last 30 Days (03/07/2026) 564.904 kWh (18.830 kWh/day) 455.640 kWh (15.188 kWh/day) -109.264 kWh (-3.642 kWh/day)
Last One Year 6.104 MWh (16.723 kWh/day) 7.842 MWh (21.485 kWh/day) 1.738 MWh (4.762 kWh/day)
Lifetime Since PTO 36.852 MWh (17.220 kW/day) 41.158 MWh (19.232 kW/day) 4.306 MWh (2.012 kW/day)
Lifetime Since Install 36.886 MWh 41.738 MWh 4.852 MWh
Voltage/Current 249.6 V / 0.0 A 249.5 V / 3.4 A 249.6 V / 3.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/06/2022 22:56 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.615 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.307 2.383 12.651 0.000 kW
2.174 kWh
0.000 kW
13.044 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.293 2.158 2.291 11.940
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.206 2.304 12.245
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 2.206 2.320 12.151
05 - 202244****** IQ7+M [0] ---- 0.000 0.294 2.006 2.148 11.354
06 - 202245****** IQ7+M [0] ---- 0.000 0.288 2.162 2.286 12.063
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 2.096 2.183 11.430 0.000 kW
2.072 kWh
0.000 kW
10.362 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.039 2.093 11.101
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 2.039 2.121 11.145
10 - 202244****** IQ7+M [0] ---- 0.000 0.295 2.085 2.191 11.446
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.103 2.213 11.586
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.274 2.329 2.329 12.494 0.000 kW
2.302 kWh
0.000 kW
9.210 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.269 2.238 2.219 12.127
14 - 202216****** IQ7+ [0] ---- 0.000 0.271 2.344 2.346 12.581
15 - 202245****** IQ7+M [0] ---- 0.000 0.265 2.299 2.307 12.389
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.16 V Current/Power -4.50 A (-0.239 kW)
Remain Capacity/Energy 502.8 Ah (25.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.8 % State Of Health 100.0 %
Run Time 4d 15h 44m to empty Report Date 2022-06-06 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack