Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.515 kW
04/06/2026 06:28 (2140 days) Production Consumption NET Usage
Now 0.000 kW 0.515 kW 0.515 kW
Today 0.000 kWh (0.000 kW) 4.029 kWh (0.620 kW) 4.029 kWh (0.620 kW)
  - This Week 4.461 kWh (3.512 kWh/day) 23.634 kWh (18.606 kWh/day) 19.173 kWh (15.094 kWh/day)
  - This Month 57.066 kWh (10.828 kWh/day) 84.693 kWh (16.070 kWh/day) 27.627 kWh (5.242 kWh/day)
  - This Year 1.286 MWh (13.503 kWh/day) 1.650 MWh (17.319 kWh/day) 0.364 MWh (3.816 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 101.302 kWh (14.472 kWh/day) 106.376 kWh (15.197 kWh/day) 5.074 kWh (0.725 kWh/day)
Last 30 Days (03/07/2026) 564.904 kWh (18.830 kWh/day) 456.709 kWh (15.224 kWh/day) -108.195 kWh (-3.606 kWh/day)
Last One Year 6.104 MWh (16.723 kWh/day) 7.842 MWh (21.485 kWh/day) 1.738 MWh (4.762 kWh/day)
Lifetime Since PTO 36.852 MWh (17.218 kW/day) 41.161 MWh (19.232 kW/day) 4.309 MWh (2.013 kW/day)
Lifetime Since Install 36.886 MWh 41.741 MWh 4.855 MWh
Voltage/Current 249.0 V / 0.0 A 248.8 V / 2.1 A 248.9 V / 2.1 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/08/2022 23:01 (14.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.104 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.294 2.404 1.499 12.268 0.000 kW
2.277 kWh
0.000 kW
13.665 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.287 2.250 1.396 11.575
03 - 202224****** IQ7+M [0] ---- 0.000 0.292 2.305 1.445 11.890
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.269 1.433 11.799
05 - 202244****** IQ7+M [0] ---- 0.000 0.289 2.148 1.309 11.030
06 - 202245****** IQ7+M [0] ---- 0.000 0.284 2.289 1.425 11.659
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.293 2.171 1.285 11.065 0.000 kW
2.148 kWh
0.000 kW
10.742 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 2.082 1.275 10.786
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 2.092 1.285 10.806
10 - 202244****** IQ7+M [0] ---- 0.000 0.292 2.184 1.291 11.033
11 - 202224****** IQ7+M [0] ---- 0.000 0.292 2.213 1.303 11.189
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.280 2.211 1.712 12.360 0.000 kW
2.174 kWh
0.000 kW
8.698 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.279 2.106 1.712 12.045
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 2.210 1.733 12.481
15 - 202245****** IQ7+M [0] ---- 0.000 0.274 2.170 1.715 12.292
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.17 V Current/Power -4.31 A (-0.229 kW)
Remain Capacity/Energy 504.9 Ah (25.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.2 % State Of Health 100.0 %
Run Time 4d 21h 8m to empty Report Date 2022-06-08 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.