Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.842 kW
04/06/2026 01:21 (2140 days) Production Consumption NET Usage
Now 0.000 kW 0.842 kW 0.842 kW
Today 0.000 kWh (0.000 kW) 1.080 kWh (0.788 kW) 1.080 kWh (0.788 kW)
  - This Week 4.461 kWh (4.222 kWh/day) 20.685 kWh (19.577 kWh/day) 16.224 kWh (15.355 kWh/day)
  - This Month 57.066 kWh (11.285 kWh/day) 81.744 kWh (16.166 kWh/day) 24.678 kWh (4.880 kWh/day)
  - This Year 1.286 MWh (13.534 kWh/day) 1.647 MWh (17.327 kWh/day) 0.361 MWh (3.794 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 101.302 kWh (14.472 kWh/day) 105.259 kWh (15.037 kWh/day) 3.957 kWh (0.565 kWh/day)
Last 30 Days (03/07/2026) 564.904 kWh (18.830 kWh/day) 455.637 kWh (15.188 kWh/day) -109.267 kWh (-3.642 kWh/day)
Last One Year 6.104 MWh (16.723 kWh/day) 7.842 MWh (21.485 kWh/day) 1.738 MWh (4.762 kWh/day)
Lifetime Since PTO 36.852 MWh (17.220 kW/day) 41.158 MWh (19.232 kW/day) 4.306 MWh (2.012 kW/day)
Lifetime Since Install 36.886 MWh 41.738 MWh 4.852 MWh
Voltage/Current 249.6 V / 0.0 A 249.5 V / 3.4 A 249.6 V / 3.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/07/2022 23:07 (14.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.859 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.300 1.467 1.778 13.833 0.000 kW
1.432 kWh
0.000 kW
8.590 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.397 1.699 13.099
03 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.472 1.741 13.420
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.423 1.696 13.250
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.430 1.611 12.382
06 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.402 1.714 13.219
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.366 1.621 12.487 0.000 kW
1.367 kWh
0.000 kW
6.836 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.294 1.360 1.574 12.127
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.336 1.599 12.240
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 1.374 1.621 12.582
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.400 1.667 12.692
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.297 1.360 1.698 13.460 0.000 kW
1.358 kWh
0.000 kW
5.434 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.298 1.339 1.649 12.977
14 - 202216****** IQ7+ [0] ---- 0.000 0.300 1.383 1.713 13.481
15 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.351 1.674 13.222
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.74 V Current/Power -1.95 A (-0.105 kW)
Remain Capacity/Energy 528.9 Ah (27.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.2 % State Of Health 100.0 %
Run Time 11d 7h 13m to empty Report Date 2022-07-07 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.