Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.357 kW
04/06/2026 03:04 (2140 days) Production Consumption NET Usage
Now 0.000 kW 0.357 kW 0.357 kW
Today 0.000 kWh (0.000 kW) 2.402 kWh (0.778 kW) 2.402 kWh (0.778 kW)
  - This Week 4.461 kWh (3.954 kWh/day) 22.007 kWh (19.507 kWh/day) 17.546 kWh (15.553 kWh/day)
  - This Month 57.066 kWh (11.128 kWh/day) 83.066 kWh (16.198 kWh/day) 26.000 kWh (5.070 kWh/day)
  - This Year 1.286 MWh (13.524 kWh/day) 1.648 MWh (17.328 kWh/day) 0.362 MWh (3.805 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 101.302 kWh (14.472 kWh/day) 106.091 kWh (15.156 kWh/day) 4.789 kWh (0.684 kWh/day)
Last 30 Days (03/07/2026) 564.904 kWh (18.830 kWh/day) 456.388 kWh (15.213 kWh/day) -108.516 kWh (-3.617 kWh/day)
Last One Year 6.104 MWh (16.723 kWh/day) 7.843 MWh (21.486 kWh/day) 1.739 MWh (4.763 kWh/day)
Lifetime Since PTO 36.852 MWh (17.220 kW/day) 41.159 MWh (19.232 kW/day) 4.307 MWh (2.013 kW/day)
Lifetime Since Install 36.886 MWh 41.739 MWh 4.853 MWh
Voltage/Current 243.8 V / 0.0 A 243.8 V / 1.5 A 243.8 V / 1.5 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/09/2022 23:11 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.429 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.294 2.157 1.231 12.079 0.000 kW
2.053 kWh
0.000 kW
12.316 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.287 2.039 1.125 11.430
03 - 202224****** IQ7+M [0] ---- 0.000 0.291 2.068 1.205 11.843
04 - 202232****** IQ7+ [0] ---- 0.000 0.293 2.070 1.162 11.606
05 - 202244****** IQ7+M [0] ---- 0.000 0.287 1.908 1.136 11.079
06 - 202245****** IQ7+M [0] ---- 0.000 0.282 2.074 1.144 11.543
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.284 1.961 1.095 10.970 0.000 kW
1.944 kWh
0.000 kW
9.718 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.288 1.869 1.084 10.653
09 - 202217****** IQ7+ [0] ---- 0.000 0.282 1.917 1.088 10.729
10 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.979 1.101 11.024
11 - 202224****** IQ7+M [0] ---- 0.000 0.282 1.992 1.086 11.143
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.263 2.120 1.265 11.539 0.000 kW
2.099 kWh
0.000 kW
8.394 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.262 2.039 1.254 11.189
14 - 202216****** IQ7+ [0] ---- 0.000 0.265 2.134 1.285 11.634
15 - 202245****** IQ7+M [0] ---- 0.000 0.260 2.102 1.263 11.418
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 526.5 Ah (27.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.8 % State Of Health 100.0 %
Run Time 14d 15h 0m to empty Report Date 2022-07-09 23:51
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.