Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.717 kW
04/06/2026 01:19 (2140 days) Production Consumption NET Usage
Now 0.000 kW 0.717 kW 0.717 kW
Today 0.000 kWh (0.000 kW) 1.060 kWh (0.789 kW) 1.060 kWh (0.789 kW)
  - This Week 4.461 kWh (4.227 kWh/day) 20.665 kWh (19.579 kWh/day) 16.204 kWh (15.352 kWh/day)
  - This Month 57.066 kWh (11.288 kWh/day) 81.724 kWh (16.165 kWh/day) 24.658 kWh (4.877 kWh/day)
  - This Year 1.286 MWh (13.534 kWh/day) 1.647 MWh (17.327 kWh/day) 0.361 MWh (3.793 kWh/day)
Yesterday 4.461 kWh (0.186 kW) 19.605 kWh (0.817 kW) 15.144 kWh (0.631 kW)
Last 7 Days 101.302 kWh (14.472 kWh/day) 105.250 kWh (15.036 kWh/day) 3.948 kWh (0.564 kWh/day)
Last 30 Days (03/07/2026) 564.904 kWh (18.830 kWh/day) 455.624 kWh (15.187 kWh/day) -109.280 kWh (-3.643 kWh/day)
Last One Year 6.104 MWh (16.723 kWh/day) 7.842 MWh (21.485 kWh/day) 1.738 MWh (4.762 kWh/day)
Lifetime Since PTO 36.852 MWh (17.220 kW/day) 41.158 MWh (19.232 kW/day) 4.306 MWh (2.012 kW/day)
Lifetime Since Install 36.886 MWh 41.738 MWh 4.852 MWh
Voltage/Current 249.5 V / 0.0 A 249.4 V / 2.9 A 249.4 V / 2.9 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/12/2022 23:11 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 24.473 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.702 2.257 12.488 0.000 kW
1.610 kWh
0.000 kW
9.657 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.622 2.125 11.766
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.622 2.178 12.155
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.637 2.170 11.988
05 - 202244****** IQ7+M [0] ---- 0.000 0.295 1.445 1.992 11.180
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.628 2.137 11.884
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.505 2.072 11.268 0.000 kW
1.510 kWh
0.000 kW
7.552 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.518 1.965 10.935
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 1.502 2.007 11.005
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.529 2.068 11.322
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.499 2.105 11.429
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.291 1.825 2.231 12.363 0.000 kW
1.816 kWh
0.000 kW
7.264 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.294 1.798 2.125 11.986
14 - 202216****** IQ7+ [0] ---- 0.000 0.294 1.843 2.240 12.484
15 - 202245****** IQ7+M [0] ---- 0.000 0.291 1.798 2.207 12.248
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.15 V Current/Power -4.70 A (-0.250 kW)
Remain Capacity/Energy 43.2 Ah (2.2 kWh) Full Capacity/Energy 540.0 Ah (27.6 kWh)
State Of Charge 8.0 % State Of Health 90.0 %
Run Time 9h 11m to empty Report Date 2022-07-12 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.