Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.052 kW
12/23/2025 07:20 (2036 days) Production Consumption NET Usage
Now 0.000 kW -0.052 kW -0.052 kW
Today 0.000 kWh (0.000 kW) 0.018 kWh (0.002 kW) 0.018 kWh (0.002 kW)
  - This Week 22.500 kWh (9.757 kWh/day) 30.386 kWh (13.177 kWh/day) 7.886 kWh (3.420 kWh/day)
  - This Month 197.406 kWh (8.850 kWh/day) 453.667 kWh (20.338 kWh/day) 256.261 kWh (11.488 kWh/day)
  - This Year 6.066 MWh (17.026 kWh/day) 7.370 MWh (20.684 kWh/day) 1.304 MWh (3.659 kWh/day)
Yesterday 12.903 kWh (0.538 kW) 13.634 kWh (0.568 kW) 0.731 kWh (0.030 kW)
Last 7 Days 70.082 kWh (10.012 kWh/day) 158.757 kWh (22.680 kWh/day) 88.675 kWh (12.668 kWh/day)
Last 30 Days 267.161 kWh (8.905 kWh/day) 620.866 kWh (20.696 kWh/day) 353.705 kWh (11.790 kWh/day)
Last One Year 6.134 MWh (16.804 kWh/day) 7.594 MWh (20.806 kWh/day) 1.461 MWh (4.002 kWh/day)
Lifetime Since PTO 35.517 MWh (17.442 kW/day) 39.323 MWh (19.310 kW/day) 3.805 MWh (1.869 kW/day)
Lifetime Since Install 35.551 MWh 39.903 MWh 4.352 MWh
Voltage/Current 249.1 V / 0.0 A 249.3 V / -0.2 A 249.2 V / -0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/28/2022 21:30 (13.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 34.026 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.455 1.841 10.608 0.000 kW
2.355 kWh
0.000 kW
14.127 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.317 1.724 9.998
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.401 1.816 10.566
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.380 1.792 10.386
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.263 1.643 9.819
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.311 1.699 9.968
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 2.334 1.701 9.948 0.000 kW
2.312 kWh
0.000 kW
11.561 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.278 1.706 10.025
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 2.235 1.703 9.959
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.324 1.745 10.091
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.390 1.749 10.204
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.279 2.126 1.835 9.973 0.000 kW
2.085 kWh
0.000 kW
8.338 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.276 1.992 1.748 9.622
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 2.131 1.843 10.086
15 - 202245****** IQ7+M [0] ---- 0.000 0.273 2.089 1.819 9.945
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.17 V Current/Power -3.57 A (-0.190 kW)
Remain Capacity/Energy 493.5 Ah (25.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.2 % State Of Health 100.0 %
Run Time 5d 18h 14m to empty Report Date 2022-04-28 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.