Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.313 kW
05/22/2026 18:07 (2186 days) Production Consumption NET Usage
Now 0.506 kW 0.193 kW -0.313 kW
Today 29.177 kWh (1.609 kW) 2.439 kWh (0.134 kW) -26.738 kWh (-1.474 kW)
  - This Week 154.954 kWh (26.921 kWh/day) 146.603 kWh (25.470 kWh/day) -8.351 kWh (-1.451 kWh/day)
  - This Month 556.770 kWh (25.592 kWh/day) 346.325 kWh (15.919 kWh/day) -210.445 kWh (-9.673 kWh/day)
  - This Year 2.510 MWh (17.705 kWh/day) 2.406 MWh (16.973 kWh/day) -0.104 MWh (-0.732 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.506 kWh (26.929 kWh/day) 156.827 kWh (22.404 kWh/day) -31.679 kWh (-4.526 kWh/day)
Last 30 Days (04/22/2026) 720.827 kWh (24.028 kWh/day) 419.613 kWh (13.987 kWh/day) -301.214 kWh (-10.040 kWh/day)
Last One Year 6.391 MWh (17.511 kWh/day) 7.791 MWh (21.346 kWh/day) 1.400 MWh (3.835 kWh/day)
Lifetime Since PTO 38.075 MWh (17.412 kW/day) 41.917 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.109 MWh 42.497 MWh 4.387 MWh
Voltage/Current 250.2 V / 2.0 A 250.2 V / 0.8 A 250.2 V / -1.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/06/2023 22:51 (8.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.387 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.207 0.317 0.177 3.154 0.000 kW
0.301 kWh
0.000 kW
1.807 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.295 0.167 3.027
03 - 202224****** IQ7+M [5] VCOP 0.000 0.213 0.312 0.178 3.136
04 - 202232****** IQ7+ [5] VCOP 0.000 0.209 0.297 0.174 3.084
05 - 202244****** IQ7+M [5] VCOP 0.000 0.206 0.292 0.162 3.087
06 - 202245****** IQ7+M [5] VCOP 0.000 0.198 0.295 0.169 3.019
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.261 0.322 0.157 3.164 0.000 kW
0.317 kWh
0.000 kW
1.584 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.251 0.316 0.158 3.579
09 - 202217****** IQ7+ [5] VCOP 0.000 0.264 0.316 0.155 3.667
10 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.318 0.156 3.665
11 - 202224****** IQ7+M [5] VCOP 0.000 0.256 0.311 0.158 3.309
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.095 0.239 0.174 1.575 0.000 kW
0.249 kWh
0.000 kW
0.996 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.107 0.251 0.178 1.724
14 - 202216****** IQ7+ [5] VCOP 0.000 0.106 0.255 0.180 1.735
15 - 202245****** IQ7+M [5] VCOP 0.000 0.101 0.250 0.173 1.673
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.92 V Current/Power -1.47 A (-77 W)
Remain Capacity/Energy 390.0 Ah (20.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 65.0 % State Of Health 100.0 %
Run Time 11d 1h 18m to empty Report Date 2023-01-06 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.