Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.326 kW
05/22/2026 16:16 (2186 days) Production Consumption NET Usage
Now 1.367 kW 4.693 kW 3.326 kW
Today 27.212 kWh (1.670 kW) 0.393 kWh (0.024 kW) -26.819 kWh (-1.646 kW)
  - This Week 152.989 kWh (26.939 kWh/day) 144.557 kWh (25.455 kWh/day) -8.432 kWh (-1.485 kWh/day)
  - This Month 554.805 kWh (25.592 kWh/day) 344.279 kWh (15.881 kWh/day) -210.526 kWh (-9.711 kWh/day)
  - This Year 2.508 MWh (17.701 kWh/day) 2.404 MWh (16.968 kWh/day) -0.104 MWh (-0.733 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.575 kWh (26.939 kWh/day) 155.867 kWh (22.267 kWh/day) -32.708 kWh (-4.673 kWh/day)
Last 30 Days (04/22/2026) 720.021 kWh (24.001 kWh/day) 418.572 kWh (13.952 kWh/day) -301.449 kWh (-10.048 kWh/day)
Last One Year 6.390 MWh (17.507 kWh/day) 7.790 MWh (21.343 kWh/day) 1.400 MWh (3.835 kWh/day)
Lifetime Since PTO 38.074 MWh (17.412 kW/day) 41.915 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.107 MWh 42.495 MWh 4.387 MWh
Voltage/Current 249.0 V / 5.5 A 248.9 V / 18.9 A 249.0 V / 13.4 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/28/2023 23:14 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.933 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.234 1.018 0.786 3.038 0.000 kW
1.008 kWh
0.000 kW
6.046 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.229 0.995 0.754 2.910
03 - 202224****** IQ7+M [5] VCOP 0.000 0.234 1.014 0.766 3.027
04 - 202232****** IQ7+ [5] VCOP 0.000 0.230 1.015 0.767 3.003
05 - 202244****** IQ7+M [5] VCOP 0.000 0.231 1.008 0.757 2.924
06 - 202245****** IQ7+M [5] VCOP 0.000 0.227 0.996 0.756 2.911
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 0.957 0.697 2.831 0.000 kW
1.113 kWh
0.000 kW
5.563 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.126 0.802 3.071
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.184 0.909 3.273
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.185 0.910 3.280
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.111 0.841 3.102
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.116 0.549 0.483 2.149 0.000 kW
0.581 kWh
0.000 kW
2.323 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.117 0.595 0.493 2.234
14 - 202216****** IQ7+ [5] VCOP 0.000 0.118 0.597 0.499 2.250
15 - 202245****** IQ7+M [5] VCOP 0.000 0.116 0.582 0.482 2.189
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.94 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 376.2 Ah (19.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 62.7 % State Of Health 100.0 %
Run Time 10d 10h 48m to empty Report Date 2023-01-28 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.