Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.050 kW
12/23/2025 19:04 (2036 days) Production Consumption NET Usage
Now 0.000 kW 0.050 kW 0.050 kW
Today 1.363 kWh (0.071 kW) 7.549 kWh (0.396 kW) 6.186 kWh (0.324 kW)
  - This Week 23.863 kWh (8.537 kWh/day) 37.917 kWh (13.566 kWh/day) 14.054 kWh (5.028 kWh/day)
  - This Month 198.769 kWh (8.720 kWh/day) 461.198 kWh (20.232 kWh/day) 262.429 kWh (11.512 kWh/day)
  - This Year 6.068 MWh (17.006 kWh/day) 7.378 MWh (20.677 kWh/day) 1.310 MWh (3.671 kWh/day)
Yesterday 12.903 kWh (0.538 kW) 13.634 kWh (0.568 kW) 0.731 kWh (0.030 kW)
Last 7 Days 70.082 kWh (10.012 kWh/day) 158.757 kWh (22.680 kWh/day) 88.675 kWh (12.668 kWh/day)
Last 30 Days 267.161 kWh (8.905 kWh/day) 620.866 kWh (20.696 kWh/day) 353.705 kWh (11.790 kWh/day)
Last One Year 6.134 MWh (16.804 kWh/day) 7.594 MWh (20.806 kWh/day) 1.461 MWh (4.002 kWh/day)
Lifetime Since PTO 35.519 MWh (17.438 kW/day) 39.330 MWh (19.309 kW/day) 3.812 MWh (1.871 kW/day)
Lifetime Since Install 35.553 MWh 39.910 MWh 4.358 MWh
Voltage/Current 249.1 V / 0.0 A 249.0 V / 0.2 A 249.0 V / 0.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/29/2022 22:10 (10.2 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.897 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.237 1.382 1.067 5.185 0.000 kW
1.322 kWh
0.000 kW
7.935 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.232 1.281 0.999 4.933
03 - 202224****** IQ7+M [0] ---- 0.000 0.236 1.324 1.060 5.204
04 - 202232****** IQ7+ [0] ---- 0.000 0.235 1.286 1.021 5.025
05 - 202244****** IQ7+M [0] ---- 0.000 0.235 1.337 1.046 5.123
06 - 202245****** IQ7+M [0] ---- 0.000 0.230 1.324 1.021 5.005
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.282 1.417 1.001 5.177 0.000 kW
1.573 kWh
0.000 kW
7.864 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.284 1.560 1.087 5.561
09 - 202217****** IQ7+ [0] ---- 0.000 0.282 1.652 1.153 5.771
10 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.624 1.169 5.791
11 - 202224****** IQ7+M [0] ---- 0.000 0.281 1.609 1.115 5.627
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.142 0.735 0.774 3.493 0.000 kW
0.775 kWh
0.000 kW
3.099 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.142 0.789 0.775 3.627
14 - 202216****** IQ7+ [0] ---- 0.000 0.144 0.802 0.787 3.660
15 - 202245****** IQ7+M [0] ---- 0.000 0.142 0.772 0.766 3.535
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.31 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 380.1 Ah (19.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 63.4 % State Of Health 100.0 %
Run Time 13d 4h 44m to empty Report Date 2022-10-29 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.