Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.313 kW
05/22/2026 16:16 (2186 days) Production Consumption NET Usage
Now 1.409 kW 0.096 kW -1.313 kW
Today 27.199 kWh (1.670 kW) 0.364 kWh (0.022 kW) -26.835 kWh (-1.648 kW)
  - This Week 152.976 kWh (26.939 kWh/day) 144.528 kWh (25.451 kWh/day) -8.448 kWh (-1.488 kWh/day)
  - This Month 554.792 kWh (25.592 kWh/day) 344.250 kWh (15.880 kWh/day) -210.542 kWh (-9.712 kWh/day)
  - This Year 2.508 MWh (17.701 kWh/day) 2.404 MWh (16.968 kWh/day) -0.104 MWh (-0.733 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.562 kWh (26.937 kWh/day) 155.838 kWh (22.263 kWh/day) -32.724 kWh (-4.675 kWh/day)
Last 30 Days (04/22/2026) 720.023 kWh (24.001 kWh/day) 418.545 kWh (13.952 kWh/day) -301.478 kWh (-10.049 kWh/day)
Last One Year 6.390 MWh (17.507 kWh/day) 7.790 MWh (21.343 kWh/day) 1.400 MWh (3.835 kWh/day)
Lifetime Since PTO 38.074 MWh (17.412 kW/day) 41.915 MWh (19.168 kW/day) 3.841 MWh (1.757 kW/day)
Lifetime Since Install 38.107 MWh 42.495 MWh 4.387 MWh
Voltage/Current 250.6 V / 5.6 A 250.5 V / 0.4 A 250.6 V / -5.2 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/31/2023 22:45 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.094 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.202 2.193 9.834 0.000 kW
1.169 kWh
0.000 kW
7.016 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.273 1.139 2.128 9.425
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.196 2.194 9.803
04 - 202232****** IQ7+ [5] VCOP 0.000 0.292 1.200 2.193 9.826
05 - 202244****** IQ7+M [5] VCOP 0.000 0.276 1.126 2.053 9.135
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.153 2.078 9.281
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.205 2.103 9.327 0.000 kW
1.221 kWh
0.000 kW
6.105 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.219 2.209 9.852
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.205 2.173 9.774
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 1.233 2.259 9.984
11 - 202224****** IQ7+M [5] VCOP 0.000 0.303 1.242 2.282 10.076
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.218 0.928 1.673 7.706 0.000 kW
0.986 kWh
0.000 kW
3.946 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.225 0.956 1.694 7.930
14 - 202216****** IQ7+ [5] VCOP 0.000 0.232 1.031 1.785 8.320
15 - 202245****** IQ7+M [5] VCOP 0.000 0.236 1.031 1.773 8.290
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.514 kWh
0.000 kW
3.028 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.237 3.028 2.883 22.005
Panel Layout Each Group Production
Last 7 days
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.