Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.689 kW
07/18/2025 00:57 (1878 days) Production Consumption NET Usage
Now 0.000 kW 0.689 kW 0.689 kW
Today 0.000 kWh (0.000 kW) 1.069 kWh (1.105 kW) 1.069 kWh (1.105 kW)
  - This Week 109.297 kWh (21.681 kWh/day) 176.615 kWh (35.035 kWh/day) 67.318 kWh (13.354 kWh/day)
  - This Month 406.375 kWh (23.847 kWh/day) 673.473 kWh (39.521 kWh/day) 267.098 kWh (15.674 kWh/day)
  - This Year 3.436 MWh (17.350 kWh/day) 3.801 MWh (19.192 kWh/day) 0.365 MWh (1.841 kWh/day)
Yesterday 22.953 kWh (0.956 kW) 36.558 kWh (1.523 kW) 13.605 kWh (0.567 kW)
Last 7 Days 160.969 kWh (22.996 kWh/day) 281.713 kWh (40.246 kWh/day) 120.744 kWh (17.250 kWh/day)
Last 30 Days 708.321 kWh (23.610 kWh/day) 1108.410 kWh (36.946 kWh/day) 400.089 kWh (13.336 kWh/day)
Last One Year 6.254 MWh (17.135 kWh/day) 6.567 MWh (17.993 kWh/day) 0.313 MWh (0.858 kWh/day)
Lifetime Since PTO 32.887 MWh (17.511 kW/day) 35.753 MWh (19.037 kW/day) 2.866 MWh (1.526 kW/day)
Lifetime Since Install 32.921 MWh 36.333 MWh 3.412 MWh
Voltage/Current 250.7 V / 0.0 A 250.5 V / 2.7 A 250.6 V / 2.7 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/10/2022 23:08 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.190 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.287 2.350 2.157 12.445 0.000 kW
2.230 kWh
0.000 kW
13.381 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.283 2.211 2.037 11.735
03 - 202224****** IQ7+M [0] ---- 0.000 0.289 2.265 2.069 12.137
04 - 202232****** IQ7+ [0] ---- 0.000 0.292 2.267 2.069 11.907
05 - 202244****** IQ7+M [0] ---- 0.000 0.285 2.062 1.907 11.261
06 - 202245****** IQ7+M [0] V--- 0.000 0.278 2.226 2.074 11.875
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.286 2.138 1.962 11.234 0.000 kW
2.113 kWh
0.000 kW
10.565 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.288 2.061 1.869 10.915
09 - 202217****** IQ7+ [0] ---- 0.000 0.285 2.056 1.917 11.016
10 - 202244****** IQ7+M [0] ---- 0.000 0.285 2.142 1.979 11.302
11 - 202224****** IQ7+M [0] ---- 0.000 0.285 2.168 1.991 11.399
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.265 2.345 2.120 12.038 0.000 kW
2.311 kWh
0.000 kW
9.244 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.262 2.236 2.040 11.679
14 - 202216****** IQ7+ [0] ---- 0.000 0.267 2.365 2.134 12.140
15 - 202245****** IQ7+M [0] ---- 0.000 0.264 2.299 2.102 11.919
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.19 V Current/Power -4.72 A (-0.251 kW)
Remain Capacity/Energy 498.3 Ah (25.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.1 % State Of Health 100.0 %
Run Time 4d 9h 34m to empty Report Date 2022-07-10 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.