Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.087 kW
05/22/2026 18:49 (2186 days) Production Consumption NET Usage
Now 0.327 kW 0.240 kW -0.087 kW
Today 29.466 kWh (1.565 kW) 2.987 kWh (0.159 kW) -26.479 kWh (-1.406 kW)
  - This Week 155.243 kWh (26.836 kWh/day) 147.151 kWh (25.437 kWh/day) -8.092 kWh (-1.399 kWh/day)
  - This Month 557.059 kWh (25.572 kWh/day) 346.873 kWh (15.923 kWh/day) -210.186 kWh (-9.648 kWh/day)
  - This Year 2.510 MWh (17.704 kWh/day) 2.407 MWh (16.974 kWh/day) -0.104 MWh (-0.730 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.254 kWh (26.893 kWh/day) 157.005 kWh (22.429 kWh/day) -31.249 kWh (-4.464 kWh/day)
Last 30 Days (04/22/2026) 720.965 kWh (24.032 kWh/day) 419.969 kWh (13.999 kWh/day) -300.996 kWh (-10.033 kWh/day)
Last One Year 6.392 MWh (17.511 kWh/day) 7.792 MWh (21.347 kWh/day) 1.400 MWh (3.836 kWh/day)
Lifetime Since PTO 38.076 MWh (17.412 kW/day) 41.917 MWh (19.168 kW/day) 3.842 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.497 MWh 4.388 MWh
Voltage/Current 250.2 V / 1.3 A 250.2 V / 1.0 A 250.2 V / -0.3 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/13/2023 23:38 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.141 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.963 1.139 10.737 0.000 kW
1.872 kWh
0.000 kW
11.231 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.866 1.091 9.997
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.890 1.129 10.272
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.913 1.140 10.471
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.683 1.082 9.282
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.915 1.107 10.280
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.817 1.058 9.486 0.000 kW
1.816 kWh
0.000 kW
9.081 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.780 1.062 9.503
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.810 1.067 9.569
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.827 1.069 9.566
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.847 1.076 9.723
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.293 1.748 1.023 10.373 0.000 kW
1.784 kWh
0.000 kW
7.134 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.296 1.746 1.067 10.605
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.823 1.103 10.974
15 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.817 1.107 11.001
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.847 kWh
0.000 kW
1.695 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.230 1.695 2.433 9.541
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.18 V Current/Power -4.64 A (-0.247 kW)
Remain Capacity/Energy 386.4 Ah (19.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 64.4 % State Of Health 100.0 %
Run Time 3d 11h 17m to empty Report Date 2023-06-13 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.