Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 4.666 kW
05/22/2026 19:36 (2186 days) Production Consumption NET Usage
Now 0.058 kW 4.724 kW 4.666 kW
Today 29.584 kWh (1.508 kW) 3.472 kWh (0.177 kW) -26.112 kWh (-1.331 kW)
  - This Week 155.361 kWh (26.706 kWh/day) 147.636 kWh (25.378 kWh/day) -7.725 kWh (-1.328 kWh/day)
  - This Month 557.177 kWh (25.539 kWh/day) 347.358 kWh (15.922 kWh/day) -209.819 kWh (-9.617 kWh/day)
  - This Year 2.510 MWh (17.700 kWh/day) 2.407 MWh (16.973 kWh/day) -0.103 MWh (-0.727 kWh/day)
Yesterday 8.982 kWh (0.374 kW) 14.480 kWh (0.603 kW) 5.498 kWh (0.229 kW)
Last 7 Days 188.279 kWh (26.897 kWh/day) 157.256 kWh (22.465 kWh/day) -31.023 kWh (-4.432 kWh/day)
Last 30 Days (04/22/2026) 721.012 kWh (24.034 kWh/day) 419.770 kWh (13.992 kWh/day) -301.242 kWh (-10.041 kWh/day)
Last One Year 6.392 MWh (17.512 kWh/day) 7.791 MWh (21.345 kWh/day) 1.399 MWh (3.834 kWh/day)
Lifetime Since PTO 38.076 MWh (17.412 kW/day) 41.918 MWh (19.168 kW/day) 3.842 MWh (1.757 kW/day)
Lifetime Since Install 38.110 MWh 42.498 MWh 4.388 MWh
Voltage/Current 248.0 V / 0.2 A 248.1 V / 19.0 A 248.1 V / 18.8 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/23/2023 23:34 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.437 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.928 2.121 10.504 0.000 kW
1.819 kWh
0.000 kW
10.915 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.794 1.970 9.917
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.833 2.009 10.212
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.881 2.057 10.339
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.631 1.808 9.403
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.847 2.037 10.149
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.710 1.902 9.650 0.000 kW
1.718 kWh
0.000 kW
8.588 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.721 1.867 9.514
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.705 1.886 9.597
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.707 1.903 9.683
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.744 1.942 9.807
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.252 1.915 2.068 9.531 0.000 kW
1.953 kWh
0.000 kW
7.813 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.257 1.934 2.072 9.699
14 - 202216****** IQ7+ [5] VCOP 0.000 0.258 1.979 2.124 10.068
15 - 202245****** IQ7+M [5] VCOP 0.000 0.259 1.986 2.132 10.109
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.061 kWh
0.000 kW
2.122 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.230 2.122 2.037 9.003
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 52.65 V Current/Power -9.19 A (-0.484 kW)
Remain Capacity/Energy 341.7 Ah (17.5 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.6 % State Of Health 98.9 %
Run Time 1d 13h 11m to empty Report Date 2023-07-23 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.