Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.399 kW
07/18/2025 14:27 (1878 days) Production Consumption NET Usage
Now 3.919 kW 2.520 kW -1.399 kW
Today 15.829 kWh (1.094 kW) 11.418 kWh (0.789 kW) -4.411 kWh (-0.305 kW)
  - This Week 125.126 kWh (22.331 kWh/day) 186.964 kWh (33.366 kWh/day) 61.838 kWh (11.036 kWh/day)
  - This Month 422.204 kWh (23.985 kWh/day) 683.822 kWh (38.846 kWh/day) 261.618 kWh (14.862 kWh/day)
  - This Year 3.452 MWh (17.381 kWh/day) 3.811 MWh (19.189 kWh/day) 0.359 MWh (1.808 kWh/day)
Yesterday 22.953 kWh (0.956 kW) 36.558 kWh (1.523 kW) 13.605 kWh (0.567 kW)
Last 7 Days 160.969 kWh (22.996 kWh/day) 281.713 kWh (40.246 kWh/day) 120.744 kWh (17.250 kWh/day)
Last 30 Days 708.321 kWh (23.610 kWh/day) 1108.410 kWh (36.946 kWh/day) 400.089 kWh (13.336 kWh/day)
Last One Year 6.254 MWh (17.135 kWh/day) 6.567 MWh (17.993 kWh/day) 0.313 MWh (0.858 kWh/day)
Lifetime Since PTO 32.903 MWh (17.515 kW/day) 35.763 MWh (19.037 kW/day) 2.860 MWh (1.523 kW/day)
Lifetime Since Install 32.937 MWh 36.343 MWh 3.406 MWh
Voltage/Current 249.4 V / 15.7 A 249.3 V / 10.1 A 249.3 V / -5.6 A
Meter Accumulated Grid Votlage Power
Conumption Net Usage Production

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/19/2022 21:38 (11.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.540 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.116 1.712 11.210 0.000 kW
1.081 kWh
0.000 kW
6.488 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.068 1.636 10.763
03 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.113 1.718 11.227
04 - 202232****** IQ7+ [5] VCOP 0.000 0.286 1.079 1.666 10.980
05 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.071 1.651 10.775
06 - 202245****** IQ7+M [5] VCOP 0.000 0.282 1.041 1.610 10.487
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 0.932 1.708 10.988 0.000 kW
1.022 kWh
0.000 kW
5.108 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.056 1.782 11.504
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.037 1.789 11.343
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.038 1.801 11.512
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 1.045 1.799 11.548
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.198 0.994 1.302 8.983 0.000 kW
0.986 kWh
0.000 kW
3.944 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.198 0.996 1.291 8.874
14 - 202216****** IQ7+ [5] VCOP 0.000 0.199 0.982 1.300 9.037
15 - 202245****** IQ7+M [5] VCOP 0.000 0.196 0.973 1.280 8.803
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
Last 7 days

Battery History
Voltage 53.14 V Current/Power -4.61 A (-0.245 kW)
Remain Capacity/Energy 494.4 Ah (25.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.4 % State Of Health 100.0 %
Run Time 4d 11h 14m to empty Report Date 2022-09-19 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.